Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The CardioCel device is a cardiovascular patch prepared from glutaraldehyde-crosslinked bovine pericardium using ADAPT TEP technology. It is a sterile, off-white, moist, pre-cut, flat sheet of acellular collagen.
ADMEDUS REGEN PTY LTD
UC0508A
In Commercial Distribution

  • 09348992000198 ()

  • Length: 5 Centimeter
  • Width: 8 Centimeter
C0508

  • Cardiovascular patch, animal-derived
The CardioCel device is a cardiovascular patch prepared from glutaraldehyde-crosslinked bovine pericardium using ADAPT TEP technology. It is a sterile, off-white, moist, pre-cut, flat sheet of acellular collagen.
ADMEDUS REGEN PTY LTD
UC0404A
In Commercial Distribution

  • 09348992000181 ()

  • Length: 4 Centimeter
  • Width: 4 Centimeter
C0404

  • Cardiovascular patch, animal-derived
The CardioCel device is a cardiovascular patch prepared from glutaraldehyde-crosslinked bovine pericardium using ADAPT TEP technology. It is a sterile, off-white, moist, pre-cut, flat sheet of acellular collagen
ADMEDUS REGEN PTY LTD
UC0508N
In Commercial Distribution

  • 09348992000150 ()

  • Width: 8 Centimeter
  • Length: 5 Centimeter
C0508

  • Cardiovascular patch, animal-derived
The CardioCel device is a cardiovascular patch prepared from glutaraldehyde-crosslinked bovine pericardium using ADAPT TEP technology. It is a sterile, off-white, moist, pre-cut, flat sheet acellular collagen.
ADMEDUS REGEN PTY LTD
UC0404N
In Commercial Distribution

  • 09348992000143 ()

  • Width: 4 Centimeter
  • Length: 4 Centimeter
C0404

  • Cardiovascular patch, animal-derived
The CardioCel device is a cardiovascular patch prepared from glutaraldehyde-crosslinked bovine pericardium using ADAPT TEP technology. It is a sterile, off-white, moist, pre-cut, flat sheet of acellular collagen.
ADMEDUS REGEN PTY LTD
UC0202
In Commercial Distribution

  • 09348992000105 ()

  • Width: 2 Centimeter
  • Length: 2 Centimeter
C0202

  • Cardiovascular patch, animal-derived
The CardioCel device is a cardiovascular patch prepared from glutaraldehyde-crosslinked bovine pericardium using ADAPT TEP technology. It is a sterile, light yellow to beige colored, moist, pre-cut, flat sheet of acellular collagen.
ADMEDUS REGEN PTY LTD
UC0208
In Commercial Distribution

  • 09348992000082 ()

  • Width: 8 Centimeter
  • Length: 2 Centimeter
C0208

  • Cardiovascular patch, animal-derived
The CardioCel device is a cardiovascular patch prepared from glutaraldehyde-crosslinked bovine pericardium using ADAPT TEP technology. It is a sterile, light yellow to beige coloured, moist, pre-cut, flat sheet of acellular collagen.
ADMEDUS REGEN PTY LTD
UC0614
In Commercial Distribution

  • 09348992000037 ()

  • Width: 14 Centimeter
  • Length: 6 Centimeter
C0614

  • Cardiovascular patch, animal-derived
The CardioCel device is a cardiovascular patch prepared from glutaraldehyde-crosslinked bovine pericardium using ADAPT TEP technology. It is a sterile, light yellow to beige coloured, moist, pre-cut, flat sheet of acellular collagen.
ADMEDUS REGEN PTY LTD
UC0508
In Commercial Distribution

  • 09348992000020 ()

  • Width: 8 Centimeter
  • Length: 5 Centimeter
C0508

  • Cardiovascular patch, animal-derived
The CardioCel device is a cardiovascular patch prepared from glutaraldehyde-crosslinked bovine pericardium using ADAPT TEP technology. It is a sterile, light yellow to beige coloured, moist, pre-cut, flat sheet of acellular collagen.
ADMEDUS REGEN PTY LTD
UC0404
In Commercial Distribution

  • 09348992000013 ()

  • Width: 4 Centimeter
  • Length: 4 Centimeter
C0404

  • Cardiovascular patch, animal-derived
The CardioCel device is a cardiovascular patch prepared from glutaraldehyde-crosslinked bovine pericardium using ADAPT TEP technology. It is a sterile, light yellow to beige coloured, moist, pre-cut, flat sheet of acellular collagen.
ADMEDUS REGEN PTY LTD
UC0202
In Commercial Distribution

  • 09348992000006 ()

  • Width: 2 Centimeter
  • Length: 2 Centimeter
C0202

  • Cardiovascular patch, animal-derived
The BioEnvelope is intended to securely hold a cardiac implantable electronic device to create a stable environment when implanted in the body. The cardiac implantable devices that may be used with the BioEnvelope include pacemaker pulse generators, defibrillators, or other cardiac implantable electronic devices.
AZIYO BIOLOGICS, INC.
440579
In Commercial Distribution

  • 04035479160647 ()
  • 04035479160555 ()

  • SubQ


  • Cardiovascular patch, animal-derived
The BioEnvelope is intended to securely hold a cardiac implantable electronic device to create a stable environment when implanted in the body. The cardiac implantable devices that may be used with the BioEnvelope include pacemaker pulse generators, defibrillators, or other cardiac implantable electronic devices.
AZIYO BIOLOGICS, INC.
440578
In Commercial Distribution

  • 04035479160548 ()
  • 04035479160654 ()

  • Width: 9.5 Centimeter
  • Height: 6.9 Centimeter


  • Cardiovascular patch, animal-derived
The BioEnvelope is intended to securely hold a cardiac implantable electronic device to create a stable environment when implanted in the body. The cardiac implantable devices that may be used with the BioEnvelope include pacemaker pulse generators, defibrillators, or other cardiac implantable electronic devices.
AZIYO BIOLOGICS, INC.
440577
In Commercial Distribution

  • 04035479160531 ()
  • 04035479160616 ()

  • Width: 8.0 Centimeter
  • Height: 6.9 Centimeter


  • Cardiovascular patch, animal-derived
The BioEnvelope is intended to securely hold a cardiac implantable electronic device to create a stable environment when implanted in the body. The cardiac implantable devices that may be used with the BioEnvelope include pacemaker pulse generators, defibrillators, or other cardiac implantable electronic devices.
AZIYO BIOLOGICS, INC.
440576
In Commercial Distribution

  • 04035479160524 ()
  • 04035479160623 ()

  • Width: 6.5 Centimeter
  • Height: 6.9 Centimeter


  • Cardiovascular patch, animal-derived
The BioEnvelope is intended to securely hold a cardiac implantable electronic device to create a stable environment when implanted in the body. The cardiac implantable devices that may be used with the BioEnvelope include pacemaker pulse generators, defibrillators, or other cardiac implantable electronic devices.
AZIYO BIOLOGICS, INC.
440575
In Commercial Distribution

  • 04035479160517 ()
  • 04035479160630 ()


  • Cardiovascular patch, animal-derived
Digital Transmitter for the Avery Breathing Pacemaker System
Avery Biomedical Devices Inc
NeurostimulatorTransmitter Digital
In Commercial Distribution

  • 00850252006066 ()
Spirit

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
No Description
Avery Biomedical Devices Inc
Transtelephonic Monitor
Not in Commercial Distribution

  • 00850252006059 ()
TTM

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
(902A) 2.0 m Lead Length
Avery Biomedical Devices Inc
External Antenna
In Commercial Distribution

  • 00850252006042 ()
902AL

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
(902A) 1.0 m Lead Length
Avery Biomedical Devices Inc
External Antenna
In Commercial Distribution

  • 00850252006035 ()
902A

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
No Description
Avery Biomedical Devices Inc
Neurostimulator Electrode Implant
In Commercial Distribution

  • 00850252006028 ()
E377-05

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
No Description
Avery Biomedical Devices Inc
Neurostimulator Receiver Implant
In Commercial Distribution

  • 00850252006011 ()
I-110A

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
No Description
Avery Biomedical Devices Inc
Neurostimulator Transmitter
In Commercial Distribution

  • 00850252006004 ()
MARK IV

  • Extramuscular diaphragm/phrenic nerve electrical stimulation system
Epicel (cultured epidermal autografts) is an aseptically processed wound dressing composed of the patient’s own (autologous) keratinocytes grown ex vivo in the presence of proliferation-arrested, murine (mouse) fibroblasts. Epicel consists of sheets of proliferative, autologous keratinocytes, ranging from 2 to 8 cell layers thick and is referred to as a cultured epidermal autograft. Each graft of Epicel is attached to petrolatum gauze backing with titanium surgical clips and measures a minimum of 50 cm2 in area. Epicel is authorized by Federal law for use in adult and pediatric patients who have deep dermal or full-thickness burns comprising a total body surface area greater than or equal to 30%. Epicel may be used in conjunction with split-thickness autografts, or alone in patients for whom split-thickness autografts may not be an option due to the severity and extent of their burns.
VERICEL CORPORATION
N/A
In Commercial Distribution

  • W41020AU201S1969 ()

  • Area/Surface Area: 50 Square centimeter


  • Cultured skin autograft/xenograft
Epicel (cultured epidermal autografts) is an aseptically processed wound dressing composed of the patient’s own (autologous) keratinocytes grown ex vivo in the presence of proliferation-arrested, murine (mouse) fibroblasts. Epicel consists of sheets of proliferative, autologous keratinocytes, ranging from 2 to 8 cell layers thick and is referred to as a cultured epidermal autograft. Each graft of Epicel is attached to petrolatum gauze backing with titanium surgical clips and measures approximately 50 cm2 in area. Epicel is authorized by Federal law for use in adult and pediatric patients who have deep dermal or full-thickness burns comprising a total body surface area greater than or equal to 30%. Epicel may be used in conjunction with split-thickness autografts, or alone in patients for whom split-thickness autografts may not be an option due to the severity and extent of their burns.
VERICEL CORPORATION
0
In Commercial Distribution

  • W41020AU201P0001 ()

  • Area/Surface Area: 50 Square centimeter


  • Cultured skin autograft/xenograft
Refill Kit
Medos International Sàrl
91-4287
In Commercial Distribution

  • 10886704072072 ()
914287

  • Implantable intrathecal infusion pump, programmable
Refill Kit
Codman Neuro Sciences Sàrl
91-4285US
In Commercial Distribution

  • 20886704071454 ()
  • 10886704071457 ()
914285US

  • Implantable intrathecal infusion pump, programmable
Bolus Kit
Medos International Sàrl
91-4284US
In Commercial Distribution

  • 10886704071440 ()
914284US

  • Implantable intrathecal infusion pump, programmable
Refill Kit
Medos International Sàrl
91-4288
In Commercial Distribution

  • 20886704064951 ()
  • 10886704064954 ()
914288

  • Implantable intrathecal infusion pump, programmable
Prometra II 40ml Programmable Pump
Flowonix Medical, Inc.
16827
In Commercial Distribution

  • 00810335020242 ()


  • Implantable intrathecal infusion pump, programmable
The Prometra II Programmable Pump is a sterile, battery-operated, teardrop-shaped implantable, programmable infusion pump, with a rigid titanium housing and flow controller system, which dispenses infusate into the intrathecal space through an implanted intrathecal catheter. To help increase safety, the Prometra II Pump incorporates a safety valve (flow-activated valve or FAV) that will shut off drug flow to the patient in the event a high flow rate occurs, such as during an MRI. All functions of the system (e.g., dosing) are controlled externally using a hand-held, battery-operated programmer. The Prometra II Pump contains a metal bellows drug reservoir with a capacity of 20 milliliters (mL). The reservoir propellant is stored within the rigid housing surrounding the bellows and provides the driving pressure for the pump. The driving pressure on the reservoir forces the infusate through an outlet filter (0.22 pm), and into an electronically controlled flow metering valve-accumulator subsystem. The Infumorph passes from the flow metering subsystem, into the catheter access port then into the catheter for delivery to the intrathecal space.
Flowonix Medical, Inc.
13827
In Commercial Distribution

  • 00810335020228 ()


  • Implantable intrathecal infusion pump, programmable
< 1 ... 12 13 14 15 16 ... 46 >