Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

SEEG DEPTH ELECTRODE, 8 CONTACTS, EXPLORATION LENGTH 26.5MM, Ø 0.8MM, LONG LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
In Commercial Distribution

  • 03664539000039 ()

  • Contact Spacing 3.5 Millimeters
  • Contact Length 2 Millimeters
D08-08AM

  • Depth electrode
SEEG DEPTH ELECTRODE, 5 CONTACTS, EXPLORATION LENGTH 16MM, Ø 0.8MM, SHORT LENGTH
DIXI MEDICAL
MICRODEEP DEPTH ELECTRODE
Not in Commercial Distribution

  • 03664539000022 ()

  • Contact Spacing 3.5 Millimeters
  • Contact Length 2 Millimeters
D08-05AT

  • Depth electrode
SPHENOIDAL ELECTRODE EEG CABLE 1.5MM SOCKET SET
PMT CORPORATION
2122
In Commercial Distribution

  • 10650551092862 ()
  • 00650551092865 ()
2122

  • Depth electrode
PLATINUM ELECTRODE, WITH NEEDLE AND CABLE, NON-CRIMPED, 2 LOOSE CONNECTORS
PMT CORPORATION
2102-32-09
In Commercial Distribution

  • 10650551092855 ()
  • 00650551092858 ()

  • Recording Length 0.25 Inch
  • Needle Gauge: 22 Gauge
  • Tip Size 3-5 Millimeter
  • Length: 30 Centimeter
  • Wire Gauge 36 Gauge
2102-32-09

  • Depth electrode
PLATINUM ELECTRODE, WITH NEEDLE, WITHOUT CABLE, NON-CRIMPED, BLUE DEPTH STOP ON NEEDLE
PMT CORPORATION
2102-32-05
In Commercial Distribution

  • 10650551092848 ()
  • 00650551092841 ()

  • Wire Gauge 36 Gauge
  • Length: 30 Centimeter
  • Tip Size 3-5 Millimeter
  • Needle Gauge: 22 Gauge
  • Recording Length 0.25 Inch
2102-32-05

  • Depth electrode
PLATINUM ELECTRODE, WITH NEEDLE, WITHOUT CABLE, NON-CRIMPED
PMT CORPORATION
2102-32-03
In Commercial Distribution

  • 10650551092831 ()
  • 00650551092834 ()

  • Recording Length 0.25 Inch
  • Needle Gauge: 21 Gauge
  • Tip Size 3-5 Millimeter
  • Length: 30 Centimeter
  • Wire Gauge 36 Gauge
2102-32-03

  • Depth electrode
PLATINUM ELECTRODE, WITH NEEDLE, WITHOUT CABLE, CRIMPED
PMT CORPORATION
2102-31-03
In Commercial Distribution

  • 10650551092824 ()
  • 00650551092827 ()

  • Wire Gauge 36 Gauge
  • Length: 30 Centimeter
  • Tip Size 3-5 Millimeter
  • Needle Gauge: 21 Gauge
  • Recording Length 0.25 Inch
2102-31-03

  • Depth electrode
STAINLESS STEEL ELECTRODE, WITH NEEDLE, WITHOUT CABLE, NON-CRIMPED
PMT CORPORATION
2101-32-03
In Commercial Distribution

  • 10650551092817 ()
  • 00650551092810 ()

  • Recording Length 0.25 Inch
  • Needle Gauge: 21 Gauge
  • Tip Size 3-5 Millimeter
  • Length: 30 Centimeter
  • Wire Gauge 36 Gauge
2101-32-03

  • Depth electrode
STAINLESS STEEL ELECTRODE, WITH NEEDLE, WITHOUT CABLE, CRIMPED
PMT CORPORATION
2101-31-03
In Commercial Distribution

  • 10650551092800 ()
  • 00650551092803 ()

  • Wire Gauge 36 Gauge
  • Length: 30 Centimeter
  • Tip Size 3-5 Millimeter
  • Needle Gauge: 21 Gauge
  • Recording Length 0.25 Inch
2101-31-03

  • Depth electrode
PUMP 8637-20 SM2 20ML EMAN US JUN BATRY
MEDTRONIC, INC.
8637-20
Not in Commercial Distribution

  • 00613994779229 ()

  • Total Volume: 20.0 Milliliter


  • Implantable intrathecal infusion pump, programmable
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D10L5
Not in Commercial Distribution

  • M272AU8D10L51 ()
  • 10381780036524 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D10L25
Not in Commercial Distribution

  • M272AU6D10L251 ()
  • 10381780036432 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D5L25
Not in Commercial Distribution

  • M272AU4D5L251 ()
  • 10381780036326 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L5
Not in Commercial Distribution

  • M272AU4D10L51 ()
  • 10381780036319 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L25
Not in Commercial Distribution

  • M272AU4D10L251 ()
  • 10381780036302 ()

  • 4 platinum contacts


  • Depth electrode
The Integra Sphenoidal Electrode is designed for investigative intraoperative monitoring of cortical electrical activity specifically at the undersurface of the temporal lobe. It has one platinum contact and is supplied with an insertion needle.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
EDSEP
Not in Commercial Distribution

  • M272EDSEP1 ()
  • 10381780037088 ()


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D5L25
Not in Commercial Distribution

  • M272AU8D5L251 ()
  • 10381780036531 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D10L25
Not in Commercial Distribution

  • M272AU8D10L251 ()
  • 10381780036517 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D5L25
Not in Commercial Distribution

  • M272AU6D5L251 ()
  • 10381780036456 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D10L5
Not in Commercial Distribution

  • M272AU6D10L51 ()
  • 10381780036449 ()

  • 6 platinum contacts


  • Depth electrode
< 1 ... 27 28 29 30 31 ... 77 >