SEARCH RESULTS FOR: Origin(4190 results)

Export results
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The CASSIOPEIA Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The CASSIOPEIA Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3324-0012
In Commercial Distribution

  • 08800104099960 ()
3324-0012

  • Spinal fixation plate, non-bioabsorbable
Anterior Cervical Plating System, 4.25mm dia. 20mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-20V
In Commercial Distribution

  • 90814008023847 ()

  • Height: 20 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter


  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.75mm dia. 14mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-475-14V
In Commercial Distribution

  • 90814008023809 ()

  • Height: 14 Millimeter
  • Width: 4.75 Millimeter
  • Depth: 4.75 Millimeter
ACP-475-14V

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.25mm dia. 12mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-12V
In Commercial Distribution

  • 90814008023748 ()

  • Height: 12 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter
ACP-425-12V

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.25mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-12F
In Commercial Distribution

  • 90814008023625 ()

  • Height: 12 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter
ACP-425-12F

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3.75mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-375-12F
In Commercial Distribution

  • 90814008023564 ()

  • Height: 12 Millimeter
  • Width: 3.75 Millimeter
  • Depth: 3.75 Millimeter
ACP-375-12F

  • Intervertebral-body internal spinal fixation system
primaLOK FF 45mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1145-00
In Commercial Distribution

  • 00813210021990 ()

  • Length: 45 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 40mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1140-00
In Commercial Distribution

  • 00813210021983 ()

  • Length: 40 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 35mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1135-00
In Commercial Distribution

  • 00813210021976 ()

  • Length: 35 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 30mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1130-00
In Commercial Distribution

  • 00813210021969 ()

  • Length: 30 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
< 1 ... 414 415 416 417 418 419 >