SEARCH RESULTS FOR: Origin(48 results)
VASCU-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. VASCU-GUARD is terminally sterilized using gamma irradiation. and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
VG01510
In Commercial Distribution
- 00085412818559 ()
VG01510
- Cardiovascular patch, animal-derived
VASCU-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. VASCU-GUARD is terminally sterilized using gamma irradiation. and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
VG0114
In Commercial Distribution
- 00085412818535 ()
VG0114
- Cardiovascular patch, animal-derived
VASCU-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. VASCU-GUARD is terminally sterilized using gamma irradiation. and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
VG0110
In Commercial Distribution
- 00085412818511 ()
VG0110
- Cardiovascular patch, animal-derived
VASCU-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. VASCU-GUARD is terminally sterilized using gamma irradiation. and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
VG0108
In Commercial Distribution
- 00085412818498 ()
VG0108
- Cardiovascular patch, animal-derived
VASCU-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. VASCU-GUARD is terminally sterilized using gamma irradiation. and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
VG0106
In Commercial Distribution
- 00085412818474 ()
VG0106
- Cardiovascular patch, animal-derived
PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
PG0608
In Commercial Distribution
- 00085412818443 ()
PG0608
- Cardiovascular patch, animal-derived
SUPPLE PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. SUPPLE PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
SPG1016
In Commercial Distribution
- 00085412818429 ()
SPG1016
- Cardiovascular patch, animal-derived
PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
PG0404
In Commercial Distribution
- 00085412818405 ()
PG0404
- Cardiovascular patch, animal-derived
SUPPLE PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. SUPPLE PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
SPG0814
In Commercial Distribution
- 00085412818375 ()
SPG0814
- Cardiovascular patch, animal-derived
SUPPLE PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. SUPPLE PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
SPG0608
In Commercial Distribution
- 00085412818313 ()
SPG0608
- Cardiovascular patch, animal-derived
CardioCel® 3D is prepared from bovine pericardium using the ADAPT® Tissue Processing Technology.
The pericardium is procured from cattle originating in Australia. Australia is considered as being of negligible risk
for BSE.
The device is a sterile, off-white, moist, pre-cut, flat or curved sheet of acellular collagen, presented sterile in a
solution of propylene glycol and sealed in a container impermeable to air and moisture.
ADMEDUS REGEN PTY LTD
UC0405A30
In Commercial Distribution
- 09348992000655 ()
- Width: 4 Centimeter
- Length: 5 Centimeter
- Angle: 30 degree
C0405A30
- Cardiovascular patch, animal-derived
VascuCel™ is prepared from bovine pericardium using the ADAPT® Tissue Processing Technology.
The pericardium is procured from cattle originating in Australia. Australia is considered as being of negligible risk for BSE.
The device is a sterile, off-white, moist, pre-cut, sheet of acellular collagen, presented sterile in a solution of propylene glycol and sealed in a jar impermeable to air and moisture.
ADMEDUS REGEN PTY LTD
UV1206T
In Commercial Distribution
- 09348992000341 ()
- Width: 12 Millimeter
- Length: 06 Centimeter
V1206T
- Cardiovascular patch, animal-derived
CardioCel® 3D is prepared from bovine pericardium using the ADAPT® Tissue Processing Technology.
The pericardium is procured from cattle originating in Australia. Australia is considered as being of negligible risk
for BSE.
The device is a sterile, off-white, moist, pre-cut, flat or curved sheet of acellular collagen, presented sterile in a
solution of propylene glycol and sealed in a container impermeable to air and moisture.
ADMEDUS REGEN PTY LTD
UC0405A30
In Commercial Distribution
- 09348992000334 ()
- Width: 4 Centimeter
- Length: 5 Centimeter
- Angle: 30 degree
C0405A30
- Cardiovascular patch, animal-derived
CardioCel® is prepared from bovine pericardium using the ADAPT® Tissue Processing Technology.
The pericardium is procured from cattle originating in Australia. Australia is considered as being of negligible risk for BSE.
The device is a sterile, off-white, moist, pre-cut, flat or curved sheet of acellular collagen, presented sterile in a solution of propylene glycol and sealed in a container impermeable to air and moisture.
ADMEDUS REGEN PTY LTD
UC0406A
In Commercial Distribution
- 09348992000648 ()
- Width: 4 Centimeter
- Length: 6 Centimeter
- Angle: 60 degree
C0406A
- Cardiovascular patch, animal-derived
CardioCel is prepared from bovine pericardium using the ADAPT® Tissue Processing Technology.
The pericardium is procured from cattle originating in Australia. Australia is considered as being of negligible risk for BSE.
The device is a sterile, off-white, moist, pre-cut, flat or curved sheet of acellular collagen, presented sterile in a solution of propylene glycol and sealed in a container impermeable to air and moisture
ADMEDUS REGEN PTY LTD
UC0406A
In Commercial Distribution
- 09348992000549 ()
- Angle: 60 degree
- Length: 6 Centimeter
- Width: 4 Centimeter
C0406A
- Cardiovascular patch, animal-derived
CardioCel® 3D is prepared from bovine pericardium using the ADAPT® Tissue Processing Technology.
The pericardium is procured from cattle originating in Australia. Australia is considered as being of negligible risk
for BSE.
The device is a sterile, off-white, moist, pre-cut, flat or curved sheet of acellular collagen, presented sterile in a
solution of propylene glycol and sealed in a container impermeable to air and moisture.
ADMEDUS REGEN PTY LTD
UC0406A60
In Commercial Distribution
- 09348992000358 ()
- Width: 4 Centimeter
- Length: 6 Centimeter
- Angle: 60 degree
C0406A60
- Cardiovascular patch, animal-derived
CardioCel® 3D is prepared from bovine pericardium using the ADAPT® Tissue Processing Technology.
The pericardium is procured from cattle originating in Australia. Australia is considered as being of negligible risk
for BSE.
The device is a sterile, off-white, moist, pre-cut, flat or curved sheet of acellular collagen, presented sterile in a
solution of propylene glycol and sealed in a container impermeable to air and moisture.
ADMEDUS REGEN PTY LTD
UC0307A90
In Commercial Distribution
- 09348992000327 ()
- Width: 3 Centimeter
- Length: 7 Centimeter
- Angle: 90 degree
C0307A90
- Cardiovascular patch, animal-derived
No Description
ADMEDUS REGEN PTY LTD
UC0406A
In Commercial Distribution
- 09348992000280 ()
- Width: 4 Centimeter
- Length: 6 Centimeter
- Angle: 60 degree
C0406A
- Cardiovascular patch, animal-derived