Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

SUPPLE PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. SUPPLE PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
SPG0814
In Commercial Distribution

  • 00085412818375 ()
SPG0814

  • Cardiovascular patch, animal-derived
SUPPLE PERI-GUARD is prepared from bovine pericardium cross-linked with glutaraldehyde, and treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20-25 degrees C. SUPPLE PERI-GUARD is terminally sterilized using gamma irradiation and packaged within a double-pouch system. The contents of the unopened, undamaged outer pouch are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
SPG0608
In Commercial Distribution

  • 00085412818313 ()
SPG0608

  • Cardiovascular patch, animal-derived
VASCU-GUARD Peripheral Vascular Patch is prepared from bovine pericardium which is cross-linked with glutaraldehyde. The pericardium is procured from cattle originating in the United States. VASCU-GUARD Peripheral Vascular Patch is chemically sterilized using ethanol and propylene oxide. VASCU-GUARD Peripheral Vascular Patch has been treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20 - 25°C. VASCU-GUARD Peripheral Vascular Patch is packaged in a container filled with sterile, non-pyrogenic water containing propylene oxide. The contents of the unopened, undamaged container are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
VG0209N
In Commercial Distribution

  • 00085412530925 ()
VG0209N

  • Cardiovascular patch, animal-derived
VASCU-GUARD Peripheral Vascular Patch is prepared from bovine pericardium which is cross-linked with glutaraldehyde. The pericardium is procured from cattle originating in the United States. VASCU-GUARD Peripheral Vascular Patch is chemically sterilized using ethanol and propylene oxide. VASCU-GUARD Peripheral Vascular Patch has been treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20 - 25°C. VASCU-GUARD Peripheral Vascular Patch is packaged in a container filled with sterile, non-pyrogenic water containing propylene oxide. The contents of the unopened, undamaged container are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
VG0110N
In Commercial Distribution

  • 00085412530918 ()
VG0110N

  • Cardiovascular patch, animal-derived
VASCU-GUARD Peripheral Vascular Patch is prepared from bovine pericardium which is cross-linked with glutaraldehyde. The pericardium is procured from cattle originating in the United States. VASCU-GUARD Peripheral Vascular Patch is chemically sterilized using ethanol and propylene oxide. VASCU-GUARD Peripheral Vascular Patch has been treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20 - 25°C. VASCU-GUARD Peripheral Vascular Patch is packaged in a container filled with sterile, non-pyrogenic water containing propylene oxide. The contents of the unopened, undamaged container are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
VG0108N
In Commercial Distribution

  • 00085412530895 ()
VG0108N

  • Cardiovascular patch, animal-derived
VASCU-GUARD Peripheral Vascular Patch is prepared from bovine pericardium which is cross-linked with glutaraldehyde. The pericardium is procured from cattle originating in the United States. VASCU-GUARD Peripheral Vascular Patch is chemically sterilized using ethanol and propylene oxide. VASCU-GUARD Peripheral Vascular Patch has been treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20 - 25 C. VASCU-GUARD Peripheral Vascular Patch is packaged in a container filled with sterile, non-pyrogenic water containing propylene oxide. The contents of the unopened, undamaged container are sterile.
SYNOVIS LIFE TECHNOLOGIES, INC.
VG0106N
In Commercial Distribution

  • 00085412530871 ()
VG0106N

  • Cardiovascular patch, animal-derived
SUPPLE PERI-GUARD Repair Patch is prepared from bovine pericardium cross-linked with glutaraldehyde. The tissue, procured from cattle originating in the USA is chemically sterilized using ethanol and propylene oxide, and treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25°C. SUPPLE PERI-GUARD is MR safe.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC1016SN
In Commercial Distribution

  • 00085412530710 ()
PC1016SNBIO

  • Cardiovascular patch, animal-derived
SUPPLE PERI-GUARD Repair Patch is prepared from bovine pericardium cross-linked with glutaraldehyde. The tissue, procured from cattle originating in the USA is chemically sterilized using ethanol and propylene oxide, and treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25°C. SUPPLE PERI-GUARD is MR safe.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC0814SN
In Commercial Distribution

  • 00085412530697 ()
PC0814SNBIO

  • Cardiovascular patch, animal-derived
SUPPLE PERI-GUARD Repair Patch is prepared from bovine pericardium cross-linked with glutaraldehyde. The tissue, procured from cattle originating in the USA is chemically sterilized using ethanol and propylene oxide, and treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25°C. SUPPLE PERI-GUARD is MR safe.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC0608SN
In Commercial Distribution

  • 00085412530673 ()
PC0608SNBIO

  • Cardiovascular patch, animal-derived
SUPPLE PERI-GUARD Repair Patch is prepared from bovine pericardium cross-linked with glutaraldehyde. The tissue, procured from cattle originating in the USA is chemically sterilized using ethanol and propylene oxide, and treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25°C. SUPPLE PERI-GUARD is MR safe.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC0404SN
In Commercial Distribution

  • 00085412530642 ()
PC0404SNBIO

  • Cardiovascular patch, animal-derived
Peri-Guard Repair Patch (Peri-Guard) is a biologic tissue prepared from bovine pericardium cross-linked with glutaraldehyde. The pericardium is procured from cattle originating in the United States. Peri-Guard is chemically sterilized using ethanol and propylene oxide. Peri-Guard is treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25C.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC1225N
In Commercial Distribution

  • 00085412530628 ()
PC1225NBIO

  • Cardiovascular patch, animal-derived
Peri-Guard Repair Patch (Peri-Guard) is a biologic tissue prepared from bovine pericardium cross-linked with glutaraldehyde. The pericardium is procured from cattle originating in the United States. Peri-Guard is chemically sterilized using ethanol and propylene oxide. Peri-Guard is treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25C.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC1016N
In Commercial Distribution

  • 00085412530604 ()
PC1016NBIO

  • Cardiovascular patch, animal-derived
Peri-Guard Repair Patch (Peri-Guard) is a biologic tissue prepared from bovine pericardium cross-linked with glutaraldehyde. The pericardium is procured from cattle originating in the United States. Peri-Guard is chemically sterilized using ethanol and propylene oxide. Peri-Guard is treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25C.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC0814N
In Commercial Distribution

  • 00085412530581 ()
PC0814NBIO

  • Cardiovascular patch, animal-derived
Peri-Guard Repair Patch (Peri-Guard) is a biologic tissue prepared from bovine pericardium cross-linked with glutaraldehyde. The pericardium is procured from cattle originating in the United States. Peri-Guard is chemically sterilized using ethanol and propylene oxide. Peri-Guard is treated with 1 molar sodium hydroxide for 60-75 minutes at 20-25C.
SYNOVIS LIFE TECHNOLOGIES, INC.
PC0608N
In Commercial Distribution

  • 00085412530567 ()
PC0608NBIO

  • Cardiovascular patch, animal-derived
microTargeting™ Single Frame Platinum 6x Non Sterile
FHC, INC.
35325Z-00795
In Commercial Distribution

  • 10873263007959 ()
  • 00873263007952 ()

  • Outer Diameter: 0.86 Millimeter
  • Length: 271.4 Millimeter
  • Length: 263.4 Millimeter
  • Length: 3 Millimeter
  • Impedance: Megaohms
35325Z

  • Depth electrode
microTargeting(TM) Electrodes, 5x, Sterile, Single or Array, 1 Meg, for use with NexFrame and mT Drive or NexDrive.
FHC, INC.
FC5000-00755
In Commercial Distribution

  • 10873263007553 ()
  • 00873263007556 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 0.56 Millimeter
  • Length: 234.2 Millimeter
  • Length: 249.2 Millimeter
FC5000

  • Depth electrode
microTargeting Differential Electrodes 5x, Sterile, Single and Array, DZAP(L), T=30 for use with Nexframe and STar Drive
FHC, INC.
FC2004-00752
In Commercial Distribution

  • 10873263007522 ()
  • 00873263007525 ()

  • Length: 227.2 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Length: 242.2 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
FC2004

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single and Array, D.ZAP(L) , T=30 for use with NexFrame and MT Drive or NexDrive
FHC, INC.
FC2003-00751
In Commercial Distribution

  • 10873263007515 ()
  • 00873263007518 ()

  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
  • Length: 234.2 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Impedance: Megaohms
FC2003

  • Depth electrode
microTargeting D.ZAP(L) Differential Electrode 5x, Sterile, Single, T=30 for use with Frame and STar or MT Drive
FHC, INC.
FC2002-00750
In Commercial Distribution

  • 10873263007508 ()
  • 00873263007501 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
  • Length: 256.4 Millimeter
  • Outer Diameter: 0.77 Millimeter
FC2002

  • Depth electrode
microTargeting Differential Electrode 5x, D.ZAP(L), Sterile, Array, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC2001-00749
In Commercial Distribution

  • 10873263007492 ()
  • 00873263007495 ()

  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 261.5 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
FC2001

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
34680-00746
In Commercial Distribution

  • 10873263007461 ()
  • 00873263007464 ()

  • Length: 256.4 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Length: 10 Millimeter
34680

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Array, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
22670-00745
In Commercial Distribution

  • 10873263007454 ()
  • 00873263007457 ()

  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 261.5 Millimeter
22670

  • Depth electrode
microTargeting Differential Electrodes 5x, Sterile, Single and Array, DZAP(L), T=30 for use with Nexframe and STar Drive
FHC, INC.
FC2004-00129
Not in Commercial Distribution

  • 10873263001292 ()
  • 00873263001295 ()

  • Length: 227.2 Millimeter
  • Length: 242.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 10 Millimeter
FC2004

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single and Array, D.ZAP(L) , T=30 for use with NexFrame and MT Drive or NexDrive
FHC, INC.
FC2003-00128
Not in Commercial Distribution

  • 10873263001285 ()
  • 00873263001288 ()

  • Length: 249.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 234.2 Millimeter
  • Length: 10 Millimeter
FC2003

  • Depth electrode
microTargeting D.ZAP(L) Differential Electrode 5x, Sterile, Single, T=30 for use with Frame and STar or MT Drive
FHC, INC.
FC2002-00127
Not in Commercial Distribution

  • 10873263001278 ()
  • 00873263001271 ()

  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 271.4 Millimeter
  • Length: 256.4 Millimeter
FC2002

  • Depth electrode
microTargeting Differential Electrode 5x, D.ZAP(L), Sterile, Array, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC2001-00126
Not in Commercial Distribution

  • 10873263001261 ()
  • 00873263001264 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 10 Millimeter
  • Length: 261.5 Millimeter
  • Length: 276.5 Millimeter
FC2001

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
34680-00125
Not in Commercial Distribution

  • 10873263001254 ()
  • 00873263001257 ()

  • Impedance: Megaohms
  • Length: 256.4 Millimeter
  • Length: 271.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
34680

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Array, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
22670-00124
Not in Commercial Distribution

  • 10873263001247 ()
  • 00873263001240 ()

  • Length: 261.5 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
22670

  • Depth electrode
microTargeting(TM) Electrodes, 5x, Sterile, Single or Array, 1 Meg, for use with NexFrame and mT Drive or NexDrive.
FHC, INC.
FC5000-00117
Not in Commercial Distribution

  • 10873263001179 ()
  • 00873263001172 ()

  • Length: 249.2 Millimeter
  • Length: 10 Millimeter
  • Length: 234.2 Millimeter
  • Impedance: Megaohms
  • Length: 0.56 Millimeter
FC5000

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
NeuroProbe
In Commercial Distribution

  • 17290014954974 ()
  • 07290014954977 ()
STR-94685Z-00

  • Depth electrode
< 1 ... 12 13 14 15 16 ... 52 >