Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D10L25
Not in Commercial Distribution

  • M272AU8D10L251 ()
  • 10381780036517 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D5L25
Not in Commercial Distribution

  • M272AU6D5L251 ()
  • 10381780036456 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D10L5
Not in Commercial Distribution

  • M272AU6D10L51 ()
  • 10381780036449 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU12D5L25
Not in Commercial Distribution

  • M272AU12D5L251 ()
  • 10381780036111 ()

  • 12 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU10D5L25
Not in Commercial Distribution

  • M272AU10D5L251 ()
  • 10381780036104 ()

  • 10 platinum contacts


  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Autoclavable Drive
In Commercial Distribution

  • 07290114063296 ()
750-000027-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Rev. 4
In Commercial Distribution

  • 07290114060899 ()
750-000027-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
BenGun and Microelectrode holder screws
In Commercial Distribution

  • 07290114061315 ()
344-000056-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Bengun Adapter
In Commercial Distribution

  • 07290114064156 ()
352-000212-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Bengun W/O Screws
In Commercial Distribution

  • 07290114064149 ()
700-000307-01

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
Long Bengun
In Commercial Distribution

  • 27290114064082 ()
700-020834-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
2
In Commercial Distribution

  • 27290114061104 ()
700-020834-00

  • Depth electrode
No Description
ALPHA OMEGA ENGINEERING CO. LTD.
CRW Non-XY frame Mechanical Set KIT
In Commercial Distribution

  • 27290016450952 ()
700-020834-00

  • Depth electrode
PLATINUM, 6 CONTACT, MINI CONNECTOR, REMOVABLE STYLET, FOR 2.4MM DRILL, 0.8MM OD, 2MM CONTACT LENGTH, 28.7MM RECORDING DEPTH, 5.33MM SPACING, 27CM MAIN TUBE LENGTH
PMT CORPORATION
2102-06-147
In Commercial Distribution

  • 00650551150701 ()


  • Depth electrode
PLATINUM, 6 CONTACT, MINI CONNECTOR, REMOVABLE STYLET, FOR 2.4MM DRILL, 0.8MM OD, 2MM CONTACT LENGTH, 37MM RECORDING DEPTH, 7MM SPACING, 27CM MAIN TUBE LENGTH
PMT CORPORATION
2102-06-146
In Commercial Distribution

  • 00650551150695 ()


  • Depth electrode
PLATINUM, 16 CONTACT, MINI CONNECTOR, REMOVABLE STYLET, FOR 2.4MM DRILL, 0.8MM OD, 2MM CONTACT LENGTH, 61.55MM RECORDING DEPTH, 3.97MM SPACING, 60CM MAIN TUBE LENGTH
PMT CORPORATION
2102-16-136
In Commercial Distribution

  • 00650551150626 ()


  • Depth electrode
PLATINUM, 6 CONTACT, MINI CONNECTOR, REMOVABLE STYLET, FOR 2.4MM DRILL, 0.8MM OD, 2MM CONTACT LENGTH, 19.5MM RECORDING DEPTH, 3.5MM SPACING, 60CM MAIN TUBE LENGTH
PMT CORPORATION
2102-06-131
In Commercial Distribution

  • 00650551150619 ()


  • Depth electrode
sEEG DEPTH ELECTRODE, 68.5 MICRO CONTACTS, MINI CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-16-133-NS
In Commercial Distribution

  • 00650551149989 ()


  • Depth electrode
PLATINUM DEPTH ELECTRODE, 4 MACRO CONTACTS, INLINE CONNECTOR, 1 EXIT, 1 LEAD, 2 TAIL, NON-STERILE
PMT CORPORATION
2102-04-145-NS
In Commercial Distribution

  • 00650551148272 ()


  • Depth electrode
PLATINUM DEPTH ELECTRODE, 10 MACRO CONTACTS, INLINE CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-10-036-NS
In Commercial Distribution

  • 00650551148241 ()


  • Depth electrode
< 1 2 3 4 5 ... 71 >