SEARCH RESULTS FOR: ("Make Dominican School of Philosophy")(70001 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
The Model 2740 physician programmer is designed for use by a physician to non invasively interrogate
and program the IPG. It is the only component in the Inspire system that contains software. This
programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates
with the IPG through the skin via short range radio frequency (RF) telemetry, telemetry communication
allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered
by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician
programmer tablet. The physician programmer has the capability to monitor respiratory waveforms,
program stimulation modes, adjust stimulation parameter values, and store waveforms and settings.
Inspire Medical Systems, Inc.
900-004-117
In Commercial Distribution
- 00810098650212 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 2740 physician programmer is designed for use by a physician to non invasively interrogate
and program the IPG. It is the only component in the Inspire system that contains software. This
programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates
with the IPG through the skin via short range radio frequency (RF) telemetry, telemetry communication
allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered
by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician
programmer tablet. The physician programmer has the capability to monitor respiratory waveforms,
program stimulation modes, adjust stimulation parameter values, and store waveforms and settings.
Inspire Medical Systems, Inc.
900-004-116
In Commercial Distribution
- 00810098650151 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 2740 physician programmer is designed for use by a physician to non invasively interrogate
and program the IPG. It is the only component in the Inspire system that contains software. This
programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates
with the IPG through the skin via short range radio frequency (RF) telemetry, telemetry communication
allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered
by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician
programmer tablet. The physician programmer has the capability to monitor respiratory waveforms,
program stimulation modes, adjust stimulation parameter values, and store waveforms and settings.
Inspire Medical Systems, Inc.
900-004-115
In Commercial Distribution
- 00810098650007 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
There are two NO2 filters in the LungFit PH; the main 12 hr NO2 filter (p/n 90008) that the user can change and the internal bagging 48 hr NO2 filter p/n 90009).
The purpose of the NO2 filters is to remove NO2 from the NO gas flow and to collect any particulates that may be in the gas flow path. When the main 12 hr filter is inserted, this NO2 filter communicates with the LungFit device through an RFID wireless chip that is mounted on the filter. The RFID chip on the filter tracks and updates with the filter’s remaining usage time to prevent the filter from being accidently re-used after it has been consumed. The RFID also communicates wirelessly with the Gas Monitoring CPU, as described below.
The NO2 filter includes two 1µm filters and two 5µm filters, with the NO2 filter material Sofnolime (soda lime) sandwiched between the particulate filters. Soda lime is a material that is commonly used in anesthesia CO2 absorbers.
The duration of use for each main filter is pre-established as 12 hours. The RFID tag tracks filter usage so that the remaining time is updated continually every minute and displayed on the device user interface (i.e., as Time Remaining). The Gas Monitoring CPU detects whether a filter is installed and displays the Change Filter alarm to alert the user to change/insert a new user when no NO2 filter is present. The device also displays the Change Filter alarm when the NO2 filter has been consumed (no more minutes remaining).
Beyond Air, Inc.
90008
In Commercial Distribution
- B882900081 ()
- B882900080 ()
- B882900082 ()
- Nitric oxide delivery unit, system-based
The Model 2740 physician programmer is designed for use by a physician to non-invasively interrogate and program the IPG. It is the only component in the Inspire system that contains software. This programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates with the IPG through the skin via short-range radio-frequency (RF) telemetry; telemetry communication allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician programmer tablet. The physician programmer has the capability to monitor respiratory waveforms, program stimulation modes, adjust stimulation parameter values, and store waveforms and settings. This data can also be printed via a wireless Bluetooth link to a commercial printer.
Inspire Medical Systems, Inc.
900-004-031
In Commercial Distribution
- 00855728005109 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 2740 physician programmer is designed for use by a physician to non-invasively interrogate and program the IPG. It is the only component in the Inspire system that contains software. This programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates with the IPG through the skin via short-range radio-frequency (RF) telemetry; telemetry communication allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician programmer tablet. The physician programmer has the capability to monitor respiratory waveforms, program stimulation modes, adjust stimulation parameter values, and store waveforms and settings. This data can also be printed via a wireless Bluetooth link to a commercial printer.
Inspire Medical Systems, Inc.
900-004-021
In Commercial Distribution
- 00855728005093 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 2740 physician programmer is designed for use by a physician to non-invasively interrogate and program the IPG. It is the only component in the Inspire system that contains software. This programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates with the IPG through the skin via short-range radio-frequency (RF) telemetry; telemetry communication allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician programmer tablet. The physician programmer has the capability to monitor respiratory waveforms, program stimulation modes, adjust stimulation parameter values, and store waveforms and settings. This data can also be printed via a wireless Bluetooth link to a commercial printer.
Inspire Medical Systems, Inc.
900-004-001
In Commercial Distribution
- 00855728005055 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
Paragon HDS® 100 (paflufocon D) rigid gas permeable contact lenses for daily wear and extended wear are available as lathe cut or molded firm contact lenses with spherical front and back surfaces in tinted versions. The posterior curve is selected so as to properly fit an individual eye and the anterior curve is selected to provide the necessary optical power to correct refractive error. A peripheral curve system on the posterior surface allows tear exchange between the lens and the cornea.
The Paragon HDS ®100 rigid gas permeable contact lens material is a thermoset copolymer derived from fluorosilicone acrylate monomers.
The Paragon HDS ®100 rigid gas permeable tinted lenses offer color enhancement of the eye and a handling aid for locating the lens. These products may be plasma treated.
Paragon Vision Sciences, Inc.
Paragon HDS100
In Commercial Distribution
- B22209 ()
- Orthokeratology contact lens
- Rigid-gas-permeable corrective contact lens, daily-wear
- Rigid-gas-permeable corrective contact lens, extended-wear
Paragon HDS® (paflufocon B) rigid gas permeable contact lenses for daily wear are available as lathe cut or molded firm contact lenses with spherical, aspheric, bifocal or toric anterior and/or posterior; or, bitoric surfaces in tinted versions. Paragon HDS® rigid gas permeable contact lenses for extended wear are available as lathe cut or molded firm contact lenses with spherical or aspheric anterior or posterior surfaces in tinted versions. The posterior curve is selected so as to properly fit an individual eye and the anterior curve is selected to provide the necessary optical power to correct refractive error. A peripheral curve system on the posterior surface allows tear exchange between the lens and the cornea.
The Paragon HDS® rigid gas permeable contact lens material is a thermoset copolymer derived from fluorosilicone acrylate monomers.
The Paragon HDS® rigid gas permeable tinted lenses offer color enhancement of the eye and a handling aid for locating the lens. These products may be plasma treated.
Paragon Vision Sciences, Inc.
Paragon HDS
In Commercial Distribution
- B22208 ()
- Orthokeratology contact lens
- Rigid-gas-permeable corrective contact lens, daily-wear
- Rigid-gas-permeable corrective contact lens, extended-wear
No Description
MAINSTAY MEDICAL LIMITED
6M7500-012
In Commercial Distribution
- 05391527771364 ()
- Implantable electrical stimulation device management software