Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

primaLOK FF 25mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1125-00
In Commercial Distribution

  • 00813210021952 ()

  • Length: 25 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
microTargeting Differential Electrodes 5x, Sterile, Single and Array, DZAP(L), T=30 for use with Nexframe and STar Drive
FHC, INC.
FC2004-00129
Not in Commercial Distribution

  • 10873263001292 ()
  • 00873263001295 ()

  • Length: 227.2 Millimeter
  • Length: 242.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 10 Millimeter
FC2004

  • Depth electrode
microTargeting(TM) Electrodes, 5x, Sterile, Single or Array, 1 Meg, for use with NexFrame and mT Drive or NexDrive.
FHC, INC.
FC5000-00117
Not in Commercial Distribution

  • 10873263001179 ()
  • 00873263001172 ()

  • Length: 249.2 Millimeter
  • Length: 10 Millimeter
  • Length: 234.2 Millimeter
  • Impedance: Megaohms
  • Length: 0.56 Millimeter
FC5000

  • Depth electrode
microTargeting(TM) Electrodes, 5x, Sterile, Single or Array, 1 Meg, for use with NexFrame and mT Drive or NexDrive.
FHC, INC.
FC5000-00755
In Commercial Distribution

  • 10873263007553 ()
  • 00873263007556 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 0.56 Millimeter
  • Length: 234.2 Millimeter
  • Length: 249.2 Millimeter
FC5000

  • Depth electrode
microTargeting Differential Electrodes 5x, Sterile, Single and Array, DZAP(L), T=30 for use with Nexframe and STar Drive
FHC, INC.
FC2004-00752
In Commercial Distribution

  • 10873263007522 ()
  • 00873263007525 ()

  • Length: 227.2 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Length: 242.2 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
FC2004

  • Depth electrode
microTargeting(TM) Electrode, 6x, non-sterile, for use with Nexframe(R) and STar Drive
FHC, INC.
5730R-00579
In Commercial Distribution

  • 10873263005795 ()
  • 00873263005798 ()

  • Outer Diameter: 0.56 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 242.2 Millimeter
  • Length: 227.2 Millimeter
5730R

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, DZAP(L), for use with Nexframe(R)
FHC, INC.
5035L-00576
In Commercial Distribution

  • 10873263005764 ()
  • 00873263005767 ()

  • Length: 234.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
5035L

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, for use with Nexframe(R)
FHC, INC.
5030R-00575
In Commercial Distribution

  • 10873263005757 ()
  • 00873263005750 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
  • Length: 234.2 Millimeter
5030R

  • Depth electrode
microTargeting(TM) Electrode, 6x, non-sterile, single, D.ZAP(L), for use with Platform
FHC, INC.
44935L-00573
In Commercial Distribution

  • 10873263005733 ()
  • 00873263005736 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 205.7 Millimeter
  • Length: 220.7 Millimeter
  • Outer Diameter: 0.55 Millimeter
44935L

  • Depth electrode
microTargeting(TM) Electrode, 6x, non-sterile, single, for use with Platform
FHC, INC.
44930R-00572
In Commercial Distribution

  • 10873263005726 ()
  • 00873263005729 ()

  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
  • Length: 220.7 Millimeter
  • Length: 205.7 Millimeter
44930R

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, single, T=30, for use with Frame and STar or MT Drive
FHC, INC.
34620R-00571
In Commercial Distribution

  • 10873263005719 ()
  • 00873263005712 ()

  • Length: 256.4 Millimeter
  • Length: 10 Millimeter
  • Length: 271.4 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
34620R

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), nonsterile
FHC, INC.
MTDWZN(BP)(BP8)-00439
Not in Commercial Distribution

  • 10873263004392 ()
  • 00873263004395 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.77 Millimeter
  • Length: 263.4 Millimeter
  • Length: 271.4 Millimeter
  • Length: 3 Millimeter
MTDWZN(BP)(BP8)

  • Depth electrode
microTargeting(TM) Electrode, 6x, non-sterile, D.ZAP(Z), Platform
FHC, INC.
44935Z-00256
In Commercial Distribution

  • 10873263002565 ()
  • 00873263002568 ()

  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 220.72 Millimeter
  • Length: 205.72 Millimeter
44935Z

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, single, D.ZAP(Z) T=30, for use with Frame and STar or MT Drive
FHC, INC.
34625Z-00249
In Commercial Distribution

  • 10873263002497 ()
  • 00873263002490 ()

  • Outer Diameter: 0.77 Millimeter
  • Length: 256.4 Millimeter
  • Length: 271.4 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
34625Z

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, single, DZAP(L) T=30, for use with Frame and STar or MT Drive
FHC, INC.
34625L-00248
In Commercial Distribution

  • 10873263002480 ()
  • 00873263002483 ()

  • Length: 256.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Length: 271.4 Millimeter
  • Impedance: Megaohms
34625L

  • Depth electrode
microTargeting(TM) Electrode, non sterile, 6x, Array, D.ZAP(Z), T=30 for use with frame, STar or MT Drive
FHC, INC.
22635Z-00241
In Commercial Distribution

  • 10873263002411 ()
  • 00873263002414 ()

  • Impedance: Megaohms
  • Length: 261.5 Millimeter
  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 10 Millimeter
22635Z

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, 6x, array, D.ZAP(L), T=30 for use with frame, STar or MT Drive
FHC, INC.
22635L-00240
In Commercial Distribution

  • 10873263002404 ()
  • 00873263002407 ()

  • Impedance: Megaohms
  • Length: 261.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
22635L

  • Depth electrode
microTargeting(TM) Electrode, 6x, non-sterile, Array, 1 Meg, T=30 for use with frame and STar or mT drive
FHC, INC.
22630R-00239
In Commercial Distribution

  • 10873263002398 ()
  • 00873263002391 ()

  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 261.5 Millimeter
  • Impedance: Megaohms
22630R

  • Depth electrode
microTargeting Electrode 6x, non-sterile, Array, 1 Meg, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC1003-00136
Not in Commercial Distribution

  • 10873263001360 ()
  • 00873263001363 ()

  • Length: 276.5 Millimeter
  • Length: 261.5 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
FC1003

  • Depth electrode
microTargeting Electrode 6x, non-sterile, Single, 1 Meg, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC1002-00135
Not in Commercial Distribution

  • 10873263001353 ()
  • 00873263001356 ()

  • Length: 271.4 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.77 Millimeter
  • Length: 256.4 Millimeter
  • Length: 10 Millimeter
FC1002

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single and Array, D.ZAP(L) , T=30 for use with NexFrame and MT Drive or NexDrive
FHC, INC.
FC2003-00128
Not in Commercial Distribution

  • 10873263001285 ()
  • 00873263001288 ()

  • Length: 249.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 234.2 Millimeter
  • Length: 10 Millimeter
FC2003

  • Depth electrode
microTargeting D.ZAP(L) Differential Electrode 5x, Sterile, Single, T=30 for use with Frame and STar or MT Drive
FHC, INC.
FC2002-00127
Not in Commercial Distribution

  • 10873263001278 ()
  • 00873263001271 ()

  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 271.4 Millimeter
  • Length: 256.4 Millimeter
FC2002

  • Depth electrode
microTargeting Differential Electrode 5x, D.ZAP(L), Sterile, Array, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC2001-00126
Not in Commercial Distribution

  • 10873263001261 ()
  • 00873263001264 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 10 Millimeter
  • Length: 261.5 Millimeter
  • Length: 276.5 Millimeter
FC2001

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
34680-00125
Not in Commercial Distribution

  • 10873263001254 ()
  • 00873263001257 ()

  • Impedance: Megaohms
  • Length: 256.4 Millimeter
  • Length: 271.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
34680

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Array, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
22670-00124
Not in Commercial Distribution

  • 10873263001247 ()
  • 00873263001240 ()

  • Length: 261.5 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
22670

  • Depth electrode
microTargeting™ Frame Single Tungsten 6X Non Sterile
FHC, INC.
34325Z-00793
In Commercial Distribution

  • 10873263007935 ()
  • 00873263007938 ()

  • Length: 263.4 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Length: 3 Millimeter
  • Length: 271.4 Millimeter
  • Impedance: Megaohms
34325Z

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single and Array, D.ZAP(L) , T=30 for use with NexFrame and MT Drive or NexDrive
FHC, INC.
FC2003-00751
In Commercial Distribution

  • 10873263007515 ()
  • 00873263007518 ()

  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
  • Length: 234.2 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Impedance: Megaohms
FC2003

  • Depth electrode
microTargeting D.ZAP(L) Differential Electrode 5x, Sterile, Single, T=30 for use with Frame and STar or MT Drive
FHC, INC.
FC2002-00750
In Commercial Distribution

  • 10873263007508 ()
  • 00873263007501 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
  • Length: 256.4 Millimeter
  • Outer Diameter: 0.77 Millimeter
FC2002

  • Depth electrode
microTargeting Differential Electrode 5x, D.ZAP(L), Sterile, Array, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC2001-00749
In Commercial Distribution

  • 10873263007492 ()
  • 00873263007495 ()

  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 261.5 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
FC2001

  • Depth electrode
microTargeting Electrode 5x, non-sterile, Array, 1 Meg, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC1003-00748
In Commercial Distribution

  • 10873263007485 ()
  • 00873263007488 ()

  • Length: 10 Millimeter
  • Length: 276.5 Millimeter
  • Length: 261.5 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
FC1003

  • Depth electrode
microTargeting Electrode 5x, non-sterile, Single, 1 Meg, T=30 for use with Frame, STar or MT Drive
FHC, INC.
FC1002-00747
In Commercial Distribution

  • 10873263007478 ()
  • 00873263007471 ()

  • Outer Diameter: 0.77 Millimeter
  • Length: 10 Millimeter
  • Length: 256.4 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
FC1002

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Single, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
34680-00746
In Commercial Distribution

  • 10873263007461 ()
  • 00873263007464 ()

  • Length: 256.4 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Length: 10 Millimeter
34680

  • Depth electrode
microTargeting Differential Electrode 5x, Sterile, Array, 1 Meg, T=30 for use with frame, STar or MT Drive
FHC, INC.
22670-00745
In Commercial Distribution

  • 10873263007454 ()
  • 00873263007457 ()

  • Length: 276.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 261.5 Millimeter
22670

  • Depth electrode
microTargeting™ Electrode, differential, tungsten, nonsterile
FHC, INC.
MTDWXN(AR)(MP1)-00744
In Commercial Distribution

  • 10873263007447 ()
  • 00873263007440 ()

  • Lumen/Inner Diameter: 0.55 Millimeter
  • Length: 220.72 Millimeter
  • Length: 205.72 Millimeter
  • Length: 10 Millimeter
MTDWXN(AR)(MP1)

  • Depth electrode
microTargeting™ Electrode, differential, tungsten, D.ZAP(L), nonsterile
FHC, INC.
MTDWLN(BP)(BP7)-00743
In Commercial Distribution

  • 10873263007430 ()
  • 00873263007433 ()

  • Length: 271.4 Millimeter
  • Length: 256.4 Millimeter
  • Length: 10 Millimeter
  • Lumen/Inner Diameter: 0.77 Millimeter
  • Impedance: Megaohms
MTDWLN(BP)(BP7)

  • Depth electrode
microTargeting Electrode, differential, tungsten, non-sterile
FHC, INC.
MTDWBN(AR)(DB1)-00742
In Commercial Distribution

  • 10873263007423 ()
  • 00873263007426 ()

  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
  • Length: 234.22 Millimeter
  • Length: 249.22 Millimeter
  • Length: 10 Millimeter
MTDWBN(AR)(DB1)

  • Depth electrode
microTargeting(TM) Electrode, Back loaded, Platinum/Iridium with Glass Insulation
FHC, INC.
MTBPBN(DT1)-00671
In Commercial Distribution

  • 10873263006716 ()
  • 00873263006719 ()

  • Length: 300 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.63 Millimeter
MTBPBN(DT1)

  • Depth electrode
microTargeting(TM) Electrode, differential, Platinum/Iridium, nonsterile
FHC, INC.
MTDPZN(PA)(MP1)-00641
In Commercial Distribution

  • 10873263006419 ()
  • 00873263006412 ()

  • Outer Diameter: 0.5 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 220.72 Millimeter
  • Length: 215.72 Millimeter
MTDPZN(PA)(MP1)

  • Depth electrode
microTargeting(TM) Electrode, differential, Platinum/Iridium, nonsterile
FHC, INC.
MTDPLN(PA)(MP1)-00639
In Commercial Distribution

  • 10873263006396 ()
  • 00873263006399 ()

  • Impedance: Megaohms
  • Length: 215.72 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.5 Millimeter
  • Length: 220.72 Millimeter
MTDPLN(PA)(MP1)

  • Depth electrode
microTargeting(TM) Electrode, differential, Platinum/Iridium, nonsterile
FHC, INC.
MTDPBN(PS)(PS1)-00632
In Commercial Distribution

  • 10873263006327 ()
  • 00873263006320 ()

  • Length: 271.4 Millimeter
  • Length: 256.4 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Outer Diameter: 0.86 Millimeter
MTDPBN(PS)(PS1)