SEARCH RESULTS FOR: ceac证书算不算国家职业资格证书<网址:bzw985.com>北京通州Federal(681 results)
No Description
IMPLANT DIRECT SYBRON MANUFACTURING LLC
44-000302
In Commercial Distribution
- 10841307118275 ()
44-000302
- Dental implant suprastructure, permanent, preformed
CERENOVUS ENTERPRISE 2 Vascular Reconstruction Device Stent OD (mm) 4.0 Stent Length (mm) 39 Recommended Microcatheter .021 Inch (0.533mm) Maximum Stent Foreshortening 4.3 mm Humanitarian Device USA ONLY): Authorized by Federal Law for use with embolic coils for the treatment of wide-neck, intracranial, saccular, or fusiform aneurysms arising from a parent vessel with a diameter of greater than or equal to 2.5mm and less than or equal to 4mm. Wide-neck is defined as having a neck width greater than or equal to 4mm or a dome-to-neck ratio less than 2mm. The effectiveness of this device for this use has not been demonstrated.
Medos International Sàrl
ENF403912
In Commercial Distribution
- 10886704075394 ()
ENF403912
- Bare-metal intracranial vascular stent
CERENOVUS ENTERPRISE 2 Vascular Reconstruction Device Stent OD (mm) 4.0 Stent Length (mm) 30 Recommended Microcatheter .021 Inch (0.533mm) Maximum Stent Foreshortening 2.8 mm Humanitarian Device USA ONLY): Authorized by Federal Law for use with embolic coils for the treatment of wide-neck, intracranial, saccular, or fusiform aneurysms arising from a parent vessel with a diameter of greater than or equal to 2.5mm and less than or equal to 4mm. Wide-neck is defined as having a neck width greater than or equal to 4mm or a dome-to-neck ratio less than 2mm. The effectiveness of this device for this use has not been demonstrated.
Medos International Sàrl
ENF403012
In Commercial Distribution
- 10886704075370 ()
ENF403012
- Bare-metal intracranial vascular stent
CERENOVUS ENTERPRISE 2 Vascular Reconstruction Device Stent OD (mm) 4.0 Stent Length (mm) 23 Recommended Microcatheter .021 Inch (0.533mm) Maximum Stent Foreshortening 2.0 mm Humanitarian Device USA ONLY): Authorized by Federal Law for use with embolic coils for the treatment of wide-neck, intracranial, saccular, or fusiform aneurysms arising from a parent vessel with a diameter of greater than or equal to 2.5mm and less than or equal to 4mm. Wide-neck is defined as having a neck width greater than or equal to 4mm or a dome-to-neck ratio less than 2mm. The effectiveness of this device for this use has not been demonstrated.
Medos International Sàrl
ENF402312
In Commercial Distribution
- 10886704075356 ()
ENF402312
- Bare-metal intracranial vascular stent
CERENOVUS ENTERPRISE 2 Vascular Reconstruction Device Stent OD (mm) 4.0 Stent Length (mm) 16 Recommended Microcatheter .021 Inch (0.533mm) Maximum Stent Foreshortening 1.2 mm Humanitarian Device USA ONLY): Authorized by Federal Law for use with embolic coils for the treatment of wide-neck, intracranial, saccular, or fusiform aneurysms arising from a parent vessel with a diameter of greater than or equal to 2.5mm and less than or equal to 4mm. Wide-neck is defined as having a neck width greater than or equal to 4mm or a dome-to-neck ratio less than 2mm. The effectiveness of this device for this use has not been demonstrated.
Medos International Sàrl
ENF401612
In Commercial Distribution
- 10886704075332 ()
ENF401612
- Bare-metal intracranial vascular stent
CERENOVUS ENTERPRISE 2 Vascular Reconstruction Device Stent OD (mm) 4.0 Stent Length (mm) 39 NO DISTAL TIP Recommended Microcatheter .021 Inch (0.533mm) Maximum Stent Foreshortening 4.3 mm Humanitarian Device USA ONLY): Authorized by Federal Law for use with embolic coils for the treatment of wide-neck, intracranial, saccular, or fusiform aneurysms arising from a parent vessel with a diameter of greater than or equal to 2.5mm and less than or equal to 4mm. Wide-neck is defined as having a neck width greater than or equal to 4mm or a dome-to-neck ratio less than 2mm. The effectiveness of this device for this use has not been demonstrated.
Medos International Sàrl
ENF403900
In Commercial Distribution
- 10886704075400 ()
ENF403900
- Bare-metal intracranial vascular stent
CERENOVUS ENTERPRISE 2 Vascular Reconstruction Device Stent OD (mm) 4.0 Stent Length (mm) 30 NO DISTAL TIP Recommended Microcatheter .021 Inch (0.533mm) Maximum Stent Foreshortening 2.8 mm Humanitarian Device USA ONLY): Authorized by Federal Law for use with embolic coils for the treatment of wide-neck, intracranial, saccular, or fusiform aneurysms arising from a parent vessel with a diameter of greater than or equal to 2.5mm and less than or equal to 4mm. Wide-neck is defined as having a neck width greater than or equal to 4mm or a dome-to-neck ratio less than 2mm. The effectiveness of this device for this use has not been demonstrated.
Medos International Sàrl
ENF403000
In Commercial Distribution
- 10886704075387 ()
ENF403000
- Bare-metal intracranial vascular stent
CERENOVUS ENTERPRISE 2 Vascular Reconstruction Device Stent OD (mm) 4.0 Stent Length (mm) 23 NO DISTAL TIP Recommended Microcatheter .021 Inch (0.533mm) Maximum Stent Foreshortening 2.0 mm Humanitarian Device USA ONLY): Authorized by Federal Law for use with embolic coils for the treatment of wide-neck, intracranial, saccular, or fusiform aneurysms arising from a parent vessel with a diameter of greater than or equal to 2.5mm and less than or equal to 4mm. Wide-neck is defined as having a neck width greater than or equal to 4mm or a dome-to-neck ratio less than 2mm. The effectiveness of this device for this use has not been demonstrated.
Medos International Sàrl
ENF402300
In Commercial Distribution
- 10886704075363 ()
ENF402300
- Bare-metal intracranial vascular stent
CERENOVUS ENTERPRISE 2 Vascular Reconstruction Device Stent OD (mm) 4.0 Stent Length (mm) 16 NO DISTAL TIP Recommended Microcatheter .021 Inch (0.533mm) Maximum Stent Foreshortening 1.2 mm Humanitarian Device USA ONLY): Authorized by Federal Law for use with embolic coils for the treatment of wide-neck, intracranial, saccular, or fusiform aneurysms arising from a parent vessel with a diameter of greater than or equal to 2.5mm and less than or equal to 4mm. Wide-neck is defined as having a neck width greater than or equal to 4mm or a dome-to-neck ratio less than 2mm. The effectiveness of this device for this use has not been demonstrated.
Medos International Sàrl
ENF401600
In Commercial Distribution
- 10886704075349 ()
ENF401600
- Bare-metal intracranial vascular stent
Epicel (cultured epidermal autografts) is an aseptically processed wound dressing composed of the patient’s own (autologous) keratinocytes grown ex vivo in the presence of proliferation-arrested, murine (mouse) fibroblasts. Epicel consists of sheets of proliferative, autologous keratinocytes, ranging from 2 to 8 cell layers thick and is referred to as a cultured epidermal autograft. Each graft of Epicel is attached to petrolatum gauze backing with titanium surgical clips and measures a minimum of 50 cm2 in area.
Epicel is authorized by Federal law for use in adult and pediatric patients who have deep dermal or full-thickness burns comprising a total body surface area greater than or equal to 30%. Epicel may be used in conjunction with split-thickness autografts, or alone in patients for whom split-thickness autografts may not be an option due to the severity and extent of their burns.
VERICEL CORPORATION
N/A
In Commercial Distribution
- W41020AU201S1969 ()
- Area/Surface Area: 50 Square centimeter
- Cultured skin autograft/xenograft