The AURAGEN™ Cortical Surface Electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are placed on the exposed cortical surface or inserted into the subdural space to contact the cortical surface. Cortical Electrodes are available with platinum contacts and vary in size according to the number of contacts. The type of cortical electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU1X2P
Not in Commercial Distribution

  • M272AU1X2P1 ()
  • 10381780036142 ()

  • 2 platinum contacts


  • Cortical electrode
The AURAGEN™ Cortical Surface Electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are placed on the exposed cortical surface or inserted into the subdural space to contact the cortical surface. Cortical Electrodes are available with platinum contacts and vary in size according to the number of contacts. The type of cortical electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU1X12P
Not in Commercial Distribution

  • M272AU1X12P1 ()
  • 10381780036135 ()

  • 12 platinum contacts


  • Cortical electrode
The AURAGEN™ Cortical Surface Electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are placed on the exposed cortical surface or inserted into the subdural space to contact the cortical surface. Cortical Electrodes are available with platinum contacts and vary in size according to the number of contacts. The type of cortical electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU1X10P
Not in Commercial Distribution

  • M272AU1X10P1 ()
  • 10381780036128 ()

  • 10 platinum contacts


  • Cortical electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU12D5L25
Not in Commercial Distribution

  • M272AU12D5L251 ()
  • 10381780036111 ()

  • 12 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU10D5L25
Not in Commercial Distribution

  • M272AU10D5L251 ()
  • 10381780036104 ()

  • 10 platinum contacts


  • Depth electrode
The OSV II Hydrocephalus Valve System is an implantable device for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart's right atrium. Unlike conventional valves, the OSV II Valve System is a variable resistance valve which maintains a drainage rate close to the CSF secretion rate (20 ml/hr) within the physiological range of intracranial pressure.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9OS721
Not in Commercial Distribution

  • 10381780036098 ()
  • M2729OS7211 ()

  • Flow Regulation Valve: 18-30ml/h, Distal Cath. 110cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Striped Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Burr Hole Reservoirs 6.4mm Diam.
9OS721

  • Ventriculo-peritoneal/atrial shunt
The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9OS5211
Not in Commercial Distribution

  • 10381780036050 ()
  • M2729OS52111 ()

  • Flow Regulation Valve: 8-17ml/h, Distal Cath. 110cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Burr Hole Reservoirs 6.4mm Diam.
9OS5211

  • Ventriculo-peritoneal/atrial shunt
The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9OS521
Not in Commercial Distribution

  • 10381780036043 ()
  • M2729OS5211 ()

  • Flow Regulation Valve: 8-17ml/h, Distal Cath. 110cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Striped Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Burr Hole Reservoirs 6.4mm Diam.
9OS521

  • Ventriculo-peritoneal/atrial shunt
The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9OS512P
Not in Commercial Distribution

  • M2729OS512P1 ()
  • 10381780036036 ()

  • Flow Regulation Valve: 8-17ml/h, Distal Cath. 110cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Striped Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Right Angle Guide 4.9mm Diam.
9OS512P

  • Ventriculo-peritoneal/atrial shunt
The Integra Flow Regulating Valves Low Flow (Standard, Mini) are implantable hydrocephalus valve systems for controlled cerebrospinal fluid (CSF) drainage from the ventricles to the peritoneal cavity or other appropriate drainage site such as the heart’s right atrium. Unlike conventional valves, the Integra Flow Regulating Valve Low Flow is a variable resistance valve that maintains drainage at a constant rate, between 8 and 17 ml/hr, within the physiological range of intracranial pressure.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9OS512
Not in Commercial Distribution

  • 10381780036029 ()
  • M2729OS5121 ()

  • Flow Regulation Valve: 8-17ml/h, Distal Cath. 110cm Length x 2.3mm O.D. x 1.1mm I.D. (F7), Striped Vent. Cath. 15cm Length x 2.7mm O.D. x 1.4mm I.D. (F8), Right Angle Guide 4.9mm Diam.
9OS512

  • Ventriculo-peritoneal/atrial shunt