SEARCH RESULTS FOR: 出海推广优化asa🚩TG@yuantou2048🚩最快24小时见效出海推广营销一条龙(6884 results)
Overall size 24”W x 20.5”D x 64.75”T.
9.73 Cubic ft. storage
Chamber I.D. 20”W x 17”D x 49.5”T.
Temperature Range: 90-160 F
Accuracy +/- 1 degrees F of set point
3 Adjustable shelves
Digital control
Stainless steel door
Audible and visual over-temp alarm
Data Logger
Mobile Base
Electrical:
120V, 7.5 Amp, 50/60 Hz
.49kw/hr, 1678 btu/hr
M.A.C. MEDICAL INC.
FHCSWC2460-TL-D-MB
In Commercial Distribution
- B286FHCSWC2460TLDMB1 ()
FHCSWC2460-TL-D-MB
- Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T.
3.0 Cubic ft. storage
Chamber I.D. 20”W x 17"D x 15.25”T
Temperature Range: 90-160 F
Accuracy +/- 1 degrees F
Digital control.
Glass door
Audible and visual over-temp alarm.
Keyed temperature lock for each chamber
Data Logger
Foot levelers
Mobile Stand
Electrical:
120V, 3.5 Amp, 50/60 Hz.
.45kw/hr, 1537 btu/hr.
M.A.C. MEDICAL INC.
FHCSWC1824-TL-G-D-MS
In Commercial Distribution
- B286FHCSWC1824TLGDMS1 ()
FHCSWC1824-TL-G-D-MS
- Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T.
3.0 Cubic ft. storage
Chamber I.D. 20”W x 17"D x 15.25”T
Temperature Range: 90-160 F
Accuracy +/- 1 degrees F
Digital control.
Glass door
Audible and visual over-temp alarm.
Keyed temperature lock for each chamber
Data Logger
Foot levelers
2 Pull-out bins
Electrical:
120V, 3.5 Amp, 50/60 Hz.
.45kw/hr, 1537 btu/hr.
M.A.C. MEDICAL INC.
FHCSWC1824-TL-G-D-B
In Commercial Distribution
- B286FHCSWC1824TLGDB1 ()
FHCSWC1824-TL-G-D-B
- Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T.
3.0 Cubic ft. storage
Chamber I.D. 20”W x 17"D x 15.25”T
Temperature Range: 90-160 F
Accuracy +/- 1 degrees F
Digital control.
Stainless steel door
Audible and visual over-temp alarm.
Keyed temperature lock for each chamber
Data Logger
Foot levelers
Mobile Stand
Electrical:
120V, 3.5 Amp, 50/60 Hz.
.45kw/hr, 1537 btu/hr.
M.A.C. MEDICAL INC.
FHCSWC1824-TL-D-MS
In Commercial Distribution
- B286FHCSWC1824TLDMS1 ()
FHCSWC1824-TL-D-MS
- Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T.
3.0 Cubic ft. storage
Chamber I.D. 20”W x 17"D x 15.25”T
Temperature Range: 90-160 F
Accuracy +/- 1 degrees F
Digital control.
Stainless steel door
Audible and visual over-temp alarm.
Keyed temperature lock for each chamber
Data Logger
Foot levelers
Electrical:
120V, 3.5 Amp, 50/60 Hz.
.45kw/hr, 1537 btu/hr.
M.A.C. MEDICAL INC.
FHCSWC1824-TL-D
In Commercial Distribution
- B286FHCSWC1824TLD1 ()
FHCSWC1824-TL-D
- Blanket warming cabinet, dry-heat
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MZ110N
Not in Commercial Distribution
- M2729MZ110N1 ()
- 10381780035848 ()
- 110cm Length x 2.3mm O.D. x 1.1mm I.D. (F7)
9MZ110N
- Peritoneal/atrial cerebrospinal fluid catheter
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MZ1011
Not in Commercial Distribution
- 10381780035831 ()
- M2729MZ10111 ()
- 110cm Length x 2.1mm O.D. x 1.1mm I.D. (F6)
9MZ1011
- Peritoneal/atrial cerebrospinal fluid catheter
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MZ101
Not in Commercial Distribution
- 10381780035824 ()
- M2729MZ1011 ()
- 91cm Length x 2.1mm O.D. x 1.1mm I.D. (F6)
9MZ101
- Peritoneal/atrial cerebrospinal fluid catheter
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MD101
Not in Commercial Distribution
- 10381780035664 ()
- M2729MD1011 ()
- 120cm Length x 2.7mm O.D. x1.4mm I.D. (F8)
9MD101
- Peritoneal/atrial cerebrospinal fluid catheter
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
953101
Not in Commercial Distribution
- 10381780034308 ()
- M2729531011 ()
- 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7)
953101