Overall size 24”W x 20.5”D x 64.75”T. 9.73 Cubic ft. storage Chamber I.D. 20”W x 17”D x 49.5”T. Temperature Range: 90-160 F Accuracy +/- 1 degrees F of set point 3 Adjustable shelves Digital control Stainless steel door Audible and visual over-temp alarm Data Logger Mobile Base Electrical: 120V, 7.5 Amp, 50/60 Hz .49kw/hr, 1678 btu/hr
M.A.C. MEDICAL INC.
FHCSWC2460-TL-D-MB
In Commercial Distribution

  • B286FHCSWC2460TLDMB1 ()
FHCSWC2460-TL-D-MB

  • Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control. Glass door Audible and visual over-temp alarm. Keyed temperature lock for each chamber Data Logger Foot levelers Mobile Stand Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr.
M.A.C. MEDICAL INC.
FHCSWC1824-TL-G-D-MS
In Commercial Distribution

  • B286FHCSWC1824TLGDMS1 ()
FHCSWC1824-TL-G-D-MS

  • Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control. Glass door Audible and visual over-temp alarm. Keyed temperature lock for each chamber Data Logger Foot levelers 2 Pull-out bins Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr.
M.A.C. MEDICAL INC.
FHCSWC1824-TL-G-D-B
In Commercial Distribution

  • B286FHCSWC1824TLGDB1 ()
FHCSWC1824-TL-G-D-B

  • Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control. Stainless steel door Audible and visual over-temp alarm. Keyed temperature lock for each chamber Data Logger Foot levelers Mobile Stand Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr.
M.A.C. MEDICAL INC.
FHCSWC1824-TL-D-MS
In Commercial Distribution

  • B286FHCSWC1824TLDMS1 ()
FHCSWC1824-TL-D-MS

  • Blanket warming cabinet, dry-heat
Overall size 24”W x 20.5”D x 24.5”T. 3.0 Cubic ft. storage Chamber I.D. 20”W x 17"D x 15.25”T Temperature Range: 90-160 F Accuracy +/- 1 degrees F Digital control. Stainless steel door Audible and visual over-temp alarm. Keyed temperature lock for each chamber Data Logger Foot levelers Electrical: 120V, 3.5 Amp, 50/60 Hz. .45kw/hr, 1537 btu/hr.
M.A.C. MEDICAL INC.
FHCSWC1824-TL-D
In Commercial Distribution

  • B286FHCSWC1824TLD1 ()
FHCSWC1824-TL-D

  • Blanket warming cabinet, dry-heat
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MZ110N
Not in Commercial Distribution

  • M2729MZ110N1 ()
  • 10381780035848 ()

  • 110cm Length x 2.3mm O.D. x 1.1mm I.D. (F7)
9MZ110N

  • Peritoneal/atrial cerebrospinal fluid catheter
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MZ1011
Not in Commercial Distribution

  • 10381780035831 ()
  • M2729MZ10111 ()

  • 110cm Length x 2.1mm O.D. x 1.1mm I.D. (F6)
9MZ1011

  • Peritoneal/atrial cerebrospinal fluid catheter
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MZ101
Not in Commercial Distribution

  • 10381780035824 ()
  • M2729MZ1011 ()

  • 91cm Length x 2.1mm O.D. x 1.1mm I.D. (F6)
9MZ101

  • Peritoneal/atrial cerebrospinal fluid catheter
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
9MD101
Not in Commercial Distribution

  • 10381780035664 ()
  • M2729MD1011 ()

  • 120cm Length x 2.7mm O.D. x1.4mm I.D. (F8)
9MD101

  • Peritoneal/atrial cerebrospinal fluid catheter
The peritoneal catheter is used to drain cerebrospinal fluid from the outlet of the valve unit into the peritoneum. The distal end of the catheter has four staggered rows of 6-mm slits, which are not readily visible. If the distal outlet hole of the catheter becomes obstructed, the slits open for drainage. The slits perform optimally in a saline environment after soaking for 24 hours at 37 degrees Celsius.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
953101
Not in Commercial Distribution

  • 10381780034308 ()
  • M2729531011 ()

  • 91cm Length x 2.3mm O.D. x 1.1mm I.D. (F7)
953101

  • Peritoneal/atrial cerebrospinal fluid catheter