SEARCH RESULTS FOR: (*Boise State University本科成绩单<网址:zjw211.com>白银Natsional*)(3252 results)
Nanohybrid Composite contains a new ytterbium fluoride mono-dispersed nano-sized particle which combined with regular silica and barium glass composes a state of the art nano-filler system. Nanohybrid Composite is a high viscosity composite that will resist sticking to instruments, yet will have sufficient flow to adapt to the walls of the cavity preparation. Nanohybrid Composite is radio-opaque and provides high compressive and flexural strengths along with a low water uptake. Nanohybrid Composite meets the ISO 4049 standard (Type 1, Class 2). Delivery method is .3 Gm unit dose compules. Color/Shade: A3. SDS and Instructions for use available at: https://www.scottsdental.com/nanohybrid-composite-compules-scott-s-select.html
SCOTT'S DENTAL SUPPLY L.L.C.
199-4003
In Commercial Distribution
- D77819940031 ()
- D77819940030 ()
- Weight: .3 Gram
199-4003
- Dental composite resin
Nanohybrid Composite contains a new ytterbium fluoride mono-dispersed nano-sized particle which combined with regular silica and barium glass composes a state of the art nano-filler system. Nanohybrid Composite is a high viscosity composite that will resist sticking to instruments, yet will have sufficient flow to adapt to the walls of the cavity preparation. Nanohybrid Composite is radio-opaque and provides high compressive and flexural strengths along with a low water uptake. Nanohybrid Composite meets the ISO 4049 standard (Type 1, Class 2). Delivery method is .3 Gm unit dose compules. Color/Shade: A2. SDS and Instructions for use available at: https://www.scottsdental.com/nanohybrid-composite-compules-scott-s-select.html
SCOTT'S DENTAL SUPPLY L.L.C.
199-4002
In Commercial Distribution
- D77819940021 ()
- D77819940020 ()
- Weight: .3 Gram
199-4002
- Dental composite resin
Nanohybrid Composite contains a new ytterbium fluoride mono-dispersed nano-sized particle which combined with regular silica and barium glass composes a state of the art nano-filler system. Nanohybrid Composite is a high viscosity composite that will resist sticking to instruments, yet will have sufficient flow to adapt to the walls of the cavity preparation. Nanohybrid Composite is radio-opaque and provides high compressive and flexural strengths along with a low water uptake. Nanohybrid Composite meets the ISO 4049 standard (Type 1, Class 2). Delivery method is .3 Gm unit dose compules. Color/Shade: A1. SDS and Instructions for use available at: https://www.scottsdental.com/nanohybrid-composite-compules-scott-s-select.html
SCOTT'S DENTAL SUPPLY L.L.C.
199-4001
In Commercial Distribution
- D77819940011 ()
- D77819940010 ()
- Weight: .3 Gram
199-4001
- Dental composite resin
The GREEN LASER PHOTOCOAGULATOR SYSTEM GYC-1000 is an ophthalmological photocoagulation system using a solid state laser (green laser beam) with a wavelength of 532nm. Like conventional laser photocoagulation systems, this system is used in ophthalmic surgical procedures, including retinal and macular photocoagulation, iridotomy and trabeculoplasty.
Since the GYC-1000 uses a diode laser as its pumping light source, the efficient oscillation of the 532nm laser beam can be obtained. As the GYC-1000 can be used with various kinds of delivery units, the system can be applied to transpupillary photocoagulation using the slit lamp or indirect ophthalmoscope, and to intraocular photocoagulation using the endophotocoagulation probe.
NIDEK CO.,LTD.
GYC-1000
In Commercial Distribution
- 04987669100202 ()
- General/multiple surgical frequency-doubled solid-state laser system
Description: Lancet, Push Button, 28G x 1.5mm, Purple
Instructions for use 1. Twist off the protective cap and pull it straight out. 2. Press the safety lancet body firmly against the puncture site and press the push-button to activate the device. 3. Gently apply intermittent pressure near the puncture site to obtain the required blood volume.
Warnings 1. Do not use if protective cap has been previously removed from lancet. 2. Clean the injection site prior to use following established procedure. 3. Discard used lancet into a sharps container in accordance with facility guidelines, national and state regulations.
SVS LLC
7573
In Commercial Distribution
- 10811220030404 ()
- 00811220030407 ()
- 28G x 1.5mm
7573
- Blood lancing device tip
Description: Lancet, Push Button, 17G x 2.0mm, Yellow, 100/bx
Instructions for use
1. Twist off the protective cap and pull it straight out.
2. Press the safety lancet body firmly against the puncture site and press the push-button to activate the device.
3. Gently apply intermittent pressure near the puncture site to obtain the required blood volume.
Warnings
1. Do not use if protective cap has been previously removed from lancet.
2. Clean the injection site prior to use following established procedure.
3. Discard used lancet into a sharps container in accordance with facility guidelines, national and state regulations.
SVS LLC
7571
In Commercial Distribution
- 10811220030381 ()
- 00811220030384 ()
- 17G x 2.0mm
7571
- Blood lancing device tip
Structure: composed of optical imaging system, control system and display.
Working principle: AUTO REF/KERATOMETER is to use infrared fundus reflex phase method, by launching a specific wavelength beam of infrared light, through the examiner cornea, lens and so on, finally projected onto the retina eyeball, then reflected back to the corresponding optical system, absorb the image by image sensor, after image processing, signal processing, calculate the ball lens diopter, axial column lens dioptre, column mirror, An instrument used to determine the refractive state of the human eye.
AUTO REF/KERATOMETER can move in X axis, Y axis and Z axis at the same time, with 3D automatic eye tracking function.
Ningbo Ming Sing Optical R & D Co., Ltd.
ARK-910
In Commercial Distribution
- 06971821402127 ()
- Automated ophthalmic refractometer
The medical diode laser(UTU3-G7B) is a surgical and therapeutic device designated for a wide variety of oral soft tissue procedures and dental whitening as well as for use in providing a temporary relief of minor pain.The device utilizes a solid state diode as laser energy source.The energy is delivered to the operating area by means of a delivery system consisting of a flexible fiber connecting the laser source and the handpiece. The device is activated by means of a footswitch.The UTU3-G7B employ the diodes with wavelengths of 980nm, 650nm and 450nm,it emits laser output energy in the infrared, red and blue spectra respectively.
Wuhan Pioon Technology Co., Ltd.
UTU3-G7B
In Commercial Distribution
- 06974624062109 ()
- General/multiple surgical diode laser system
The medical diode laser(UTU3-G7W) is a surgical and therapeutic device designated for a wide variety of oral soft tissue procedures and dental whitening as well as for use in providing a temporary relief of minor pain.The device utilizes a solid state diode as laser energy source.The energy is delivered to the operating area by means of a delivery system consisting of a flexible fiber connecting the laser source and the handpiece. The device is activated by means of a footswitch.The UTU3-G7W employ the diodes with wavelengths of 980nm, 650nm and 450nm,it emits laser output energy in the infrared, red and blue spectra respectively.
Wuhan Pioon Technology Co., Ltd.
UTU3-G7W
In Commercial Distribution
- 06974624062116 ()
- General/multiple surgical diode laser system
The Alethia Malaria PLUS DNA amplification assays, performed on the Alethia Incubator/Reader, are qualitative in vitro diagnostic tests for the direct detection of Plasmodium sp. DNA in human venous EDTA whole blood specimens from individuals with signs and symptoms of malarial infection. Results from Alethia Malaria assays are intended to be used as an aid in the diagnosis of human malaria infection.
Alethia Malaria assays utilize loop-mediated isothermal DNA amplification (LAMP) technology to detect Plasmodium sp. DNA by targeting segments of the Plasmodium genome. Alethia Malaria assays do not distinguish between Plasmodium species.
Alethia Malaria PLUS is intended for use in hospital, reference or state laboratory settings. The device is not intended for nonlaboratory point-of-care use.
MERIDIAN BIOSCIENCE, INC.
481125
Not in Commercial Distribution
- 00840733102257 ()
481125
- Multiple Plasmodium species nucleic acid IVD, kit, nucleic acid technique (NAT)