SEARCH RESULTS FOR: 网赚短信通道产品(唯一TG:ppo995)全球短信群发106三网国际通道.muv(13088 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
CCS CONNECTOR FOR 3 CONCENTRATES
B.Braun Avitum AG
7102868
In Commercial Distribution
- 04046964738388 ()
7102868
- Haemodialysis system, institutional
Infusomat® Space® Large Volume Pump, Non-Wireless
B. BRAUN MEDICAL INC.
8713052U
In Commercial Distribution
- 04046964708626 ()
8713052U
- Bedside infusion pump, single-channel
While rotating around the eye, the Pentacam® AXL captures Scheimpflug
images of the anterior eye segment through varying axes. The
Scheimpflug images created during an examination are transmitted to
the connected PC.
The axial length of the eye is measured and displayed by interferometry.
OCULUS Optikgeräte Gesellschaft mit beschränkter Haftung
70100
In Commercial Distribution
- 04049584012333 ()
- Weight: 7.9 Kilogram
- Height: 430 Millimeter
- Depth: 208 Millimeter
- Width: 270 Millimeter
- Corneal topography system
The OCULUS Keratograph 5M combines the keratometric measuring process
with topographic mapping.
Measurement of the corneal surface is done by means of a Placido ring
system that is reflected off the cornea. These data are analyzed by the
computer.
OCULUS Optikgeräte Gesellschaft mit beschränkter Haftung
7700
In Commercial Distribution
- 04049584000477 ()
- Weight: 6.1 Kilogram
- Height: 512 Millimeter
- Depth: 400 Millimeter
- Width: 275 Millimeter
- Corneal topography system
The PARK 1 combines three measuring functions in one unit.
Auto-Refractometer
An infrared light source projects measuring light onto the retina of the eye
from where it is reflected back to the shutter location. Sensitive sensor
chips, or CCD cameras now register the deviation of the reflected light from
the shutter location. The deviation depends on the ametropia. From that, an
integrated microcomputer calculates the ametropia in D, based on the
sphere, cylinder and cylinder axis position.
1 Measuring ocular / Patient eyepiece 4 Chin rest
2 Keratometer ring 5 Marking for the eye height
3 Pachycam camera glass cover
Keratometer
To determine the curvature of the cornea, a reflected image of the cornea
is captured by a camera sensor and is measured.
The reflection of test marks and of a ring is used as the reflected image.
This allows the central radii of the cornea to be determined.
Pachymeter
The pachymetry principle uses Scheimpflug images of the cornea, which
are analysed by a built-in computer.
600 Absolute data points are evaluated with the Scheimpflug image. The
measuring range lies on a 4 mm slit through the apex.
The slit light illuminates a sectional plane from the front surface of the cornea
to the back surface. The transparent cells of the cornea scatter the slit
light such that the sectional plane appears as if it were self-luminous.
This is captured at an angle of 45° through the pupil by a camera, whereby
the image plane of the camera is also tilted 45° to the optical axis of the
camera lens, in order to sharply focus the light-scattering cornea plane
onto the image plane of the camera (Scheimpflug image).
Thanks to this arrangement, sharp sectional images of the cornea can be attained.
OCULUS Optikgeräte Gesellschaft mit beschränkter Haftung
65000
In Commercial Distribution
- 04049584000217 ()
- Weight: 12 Kilogram
- Depth: 530 Millimeter
- Width: 538 Millimeter
- Height: 265 Millimeter
- Ophthalmic refractometer, manual
The OCULUS Easyfield® has been designed for combined use as a
screening unit with all associated options for immediate follow-up
examination of suspicious findings. The most common examination grids
and strategies for the central visual field up to 30° can be accessed.
The Easyfield® offers pre programmed combinations for often needed
examination routines. For example: Screening 24-2, SPARK Quick,
Macula. You can also combine your own routines and then save them as
a program.
OCULUS Optikgeräte Gesellschaft mit beschränkter Haftung
15005
In Commercial Distribution
- 04049584000064 ()
- Weight: 4.6 Kilogram
- Height: 435 Millimeter
- Depth: 450 Millimeter
- Width: 275 Millimeter
- Perimeter, automatic
The OCULUS Easyfield® has been designed for combined use as a
screening unit with all associated options for immediate follow-up
examination of suspicious findings. The most common examination grids
and strategies for the central visual field up to 30° can be accessed.
The Easyfield® offers pre programmed combinations for often needed
examination routines. For example: Screening 24-2, SPARK Quick,
Macula. You can also combine your own routines and then save them as
a program.
OCULUS Optikgeräte Gesellschaft mit beschränkter Haftung
15000
In Commercial Distribution
- 04049584000057 ()
- Weight: 6.8 Kilogram
- Height: 435 Millimeter
- Depth: 540 Millimeter
- Width: 316 Millimeter
- Perimeter, automatic
The Carl Zeiss Meditec MEL 90 Excimer Laser System is designed for refractive surgery based on the ablation of corneal tissue achieved with a short pulse excimer laser having a wavelength of 193 nanometers. The laser head emits 4 to 7 nanosecond pulses (FWHM nominal pulse duration) with a repetition rate of 500 Hz. The MEL 90 Excimer Laser is a spot-scanning laser that utilizes a Gaussian beam with a 0.7 mm spot diameter.
Indications for Use:
The MEL 90 is indicated for use in primary Laser-Assisted in situ Keratomileusis (LASIK) treatments for the reduction or elimination of:
• Myopia less in magnitude than -10.00 D sphere (in minus-cylinder notation), with and without cylinder up to -4.00 D, when MRSE is less in magnitude than -10.00 D;
• Hyperopia up to +4.00 D sphere (in plus-cylinder notation), with and without cylinder up to +3.00 D, when MRSE is up to +5.00 D; and
• Mixed astigmatism with cylinder from >1.00 D up to 4.00 D;
in patients who are 18 years of age or older with documentation of stable manifest refraction over the past year as demonstrated by a change in MRSE within +/- 0.50 D.
Carl Zeiss Meditec AG
1900-109
In Commercial Distribution
- 04049471095074 ()
- Weight: 295 Kilogram
- x W x H: 1.63 m x 0.73 m x 1.48 m to 1.70 m
- Ophthalmic excimer laser system
No Description
H ROBOTICS INC.
RHSW
In Commercial Distribution
- 08800101600015 ()
- Ankle continuous passive motion exerciser
- Hand/wrist continuous passive motion exerciser
- Continuous passive motion joint exerciser
DIAGNOSTIC ULTRASOUND TRANSDUCER, L15-4
FUJIFILM SONOSITE, INC.
P23120-22A
In Commercial Distribution
- 00841517111946 ()
P23120
- Extracorporeal ultrasound imaging transducer, hand-held