SEARCH RESULTS FOR: ablation(15317 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
BiClamp® LAP Forceps fenestr. Smooth; L 340 mm; OD 5 mm
Erbe Elektromedizin GmbH
20195-192
Not in Commercial Distribution
- 04050147020436 ()
20195-192
- Endoscopic electrosurgical handpiece/electrode, bipolar, reusable
Wire loops for nasal polyp snares
Ø0.3mm
Package of 100 pieces
RZ-Medizintechnik GmbH
420-210-003
In Commercial Distribution
- 04049197312486 ()
420-210-003
- Nasal snare, reusable
Snare wire in coils
Ø0.3 mm, 1 coil of 10 metres
RZ-Medizintechnik GmbH
420-210-013
In Commercial Distribution
- 04049197474399 ()
420-210-013
- Nasal snare, reusable
The Carl Zeiss Meditec MEL 90 Excimer Laser System is designed for refractive surgery based on the ablation of corneal tissue achieved with a short pulse excimer laser having a wavelength of 193 nanometers. The laser head emits 4 to 7 nanosecond pulses (FWHM nominal pulse duration) with a repetition rate of 500 Hz. The MEL 90 Excimer Laser is a spot-scanning laser that utilizes a Gaussian beam with a 0.7 mm spot diameter.
Indications for Use:
The MEL 90 is indicated for use in primary Laser-Assisted in situ Keratomileusis (LASIK) treatments for the reduction or elimination of:
• Myopia less in magnitude than -10.00 D sphere (in minus-cylinder notation), with and without cylinder up to -4.00 D, when MRSE is less in magnitude than -10.00 D;
• Hyperopia up to +4.00 D sphere (in plus-cylinder notation), with and without cylinder up to +3.00 D, when MRSE is up to +5.00 D; and
• Mixed astigmatism with cylinder from >1.00 D up to 4.00 D;
in patients who are 18 years of age or older with documentation of stable manifest refraction over the past year as demonstrated by a change in MRSE within +/- 0.50 D.
Carl Zeiss Meditec AG
1900-109
In Commercial Distribution
- 04049471095074 ()
- Weight: 295 Kilogram
- x W x H: 1.63 m x 0.73 m x 1.48 m to 1.70 m
- Ophthalmic excimer laser system
The Acessa ProVu Table Top Field Generator
Hologic, Inc.
5200
In Commercial Distribution
- 15420045515284 ()
5200
- Electromagnetic surgical navigation device tracking system field generator
BIPOLAR CORD 12FT DISP 10/BOX
Bausch & Lomb Incorporated
S2070 C
In Commercial Distribution
- 00757770458035 ()
- 20757770458039 ()
S2070 C
- Endoscopic electrosurgical handpiece/electrode, bipolar, reusable
BIPOLAR CORD 12FT DISP 10/BOX
Bausch & Lomb Incorporated
S2070 C
Not in Commercial Distribution
- 00757770454068 ()
CX9430
- Endoscopic electrosurgical handpiece/electrode, bipolar, reusable
Snares are intended to be used with snare gun for removal of tonsil and nasal polyps.
ASPEN SURGICAL PRODUCTS, INC.
2406
In Commercial Distribution
- 00887761005570 ()
- 80887761005576 ()
- 10887761005577 ()
- Nasal snare, single-use
Snares are intended to be used with snare gun for removal of tonsil and nasal polyps.
ASPEN SURGICAL PRODUCTS, INC.
2405
In Commercial Distribution
- 10887761005560 ()
- 00887761005563 ()
- 80887761005569 ()
- Nasal snare, single-use
VESSEL SEALER EXTEND
INTUITIVE SURGICAL, INC.
480422
In Commercial Distribution
- 10886874115661 ()
- 00886874115664 ()
- Outer Diameter: 8 Millimeter
- Robotic electrosurgical instrument, bipolar, single-use