The MyoPro 2x, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2x consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2x EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2x filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2x to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Right - 29858 rev1
In Commercial Distribution
- 00855846007221 ()
29858
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro 2x, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2x consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2x EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2x filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2x to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Left - 29857 rev1
In Commercial Distribution
- 00855846007214 ()
29857
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro 2+, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2+ consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2+ EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2+ filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2+ to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Right - 28463 rev1
In Commercial Distribution
- 00855846007160 ()
28463
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro 2+, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2+ consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2+ EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2+ filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2+ to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Left - 28462 rev1
In Commercial Distribution
- 00855846007153 ()
28462
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro 2+, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2+ consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2+ EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2+ filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2+ to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion W Right - 28461 rev1
In Commercial Distribution
- 00855846007146 ()
28461
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro 2+, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro 2+ consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set wrist module, a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro 2+ EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro 2+ filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro 2+ to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion W Left - 28460 rev1
In Commercial Distribution
- 00855846007139 ()
28460
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The Mobile Arm Rehabilitation Kit (MARK) is a kit containing two (left and right) MyoPro upper extremity limb orthoses. A MyoPro upper extremity limb orthosis is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MARK product consists of a combination of the following components: shoulder harnesses, adjustable limb orthoses (braces), powered elbow orthoses with surface electromyography (EMG) sensors, static or manually set multi-articulating wrists (MAW), static hand orthoses or powered hand orthoses with EMG sensors, an interchangeable battery with a separate recharging station, an MTS chafe with loop for anti-rotation strap, a laptop, and a product carrying case/bag.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. A MyoPro device filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate and complete desired motions.
Myomo, Inc.
MARK 26215
In Commercial Distribution
- 00855846007122 ()
MARK 26215
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion W Left - 25922 rev1
In Commercial Distribution
- 00855846007115 ()
25922
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion W Right - 25921 rev1
In Commercial Distribution
- 00855846007108 ()
25921
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Left - 25920 rev1
In Commercial Distribution
- 00855846007092 ()
25920
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Right - 25919 rev1
In Commercial Distribution
- 00855846007085 ()
25919
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion E Left - 25910 rev1
In Commercial Distribution
- 00855846007078 ()
25910
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion E Right - 25909 rev1
In Commercial Distribution
- 00855846007061 ()
25909
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion E Right - 25746
In Commercial Distribution
- 00855846007054 ()
25746
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion E Left - 25744
In Commercial Distribution
- 00855846007047 ()
25744
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion W Right - 25742
In Commercial Distribution
- 00855846007030 ()
25742
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion W Left - 25738
In Commercial Distribution
- 00855846007023 ()
25738
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Right - 25740
In Commercial Distribution
- 00855846007016 ()
25740
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
The MyoPro, an upper extremity limb orthosis, is an assistive device that supports a weakened or deformed limb for functional improvement. The user’s electromyography (EMG) muscle activity is used to voluntarily control the impaired limb.
The MyoPro consists of a combination of the following components: a shoulder harness, a custom-made upper limb orthosis (brace), a powered elbow orthosis with surface electromyography (EMG) sensors, a static or manually set multi-articulating wrist (MAW), a static hand orthosis or powered hand orthosis with EMG sensors, and an interchangeable battery with a separate recharging station.
The MyoPro’s EMG-control circuit continuously monitors and senses, but does not stimulate, the User’s muscles. The MyoPro filters and processes the EMG signal, and translates this information into motor movement. Based on the User’s needs and abilities, the control parameters are adjusted by the User’s Provider. The power assist moves the motor with speed proportional to User’s exertion. This system enables the MyoPro to assist the User to initiate
and complete desired motions.
Myomo, Inc.
Motion G Left - 25736
In Commercial Distribution
- 00855846007009 ()
25736
- Psychophysiological biofeedback system
- Elbow orthosis
- Hand orthosis
ImagenSPECT™ 3.0 is a Windows application which allows physicians and healthcare professionals to inspect, reconstruct and reorient myocardial perfusion SPECT images. The system processes gated and ungated SPECT cardiac images to create 3D tomographic data. The user can correct for patient motion, change filter settings, change reconstruction settings, range of reconstruction, and reorientation angles. The application also models the influence of distance dependent blur. The use of this system is limited to qualified, licensed healthcare providers (radiologists, nuclear cardiologists or nuclear medicine physicians) trained in the use of nuclear medicine imaging devices.
This software also processes, display and performs quantitative calculations of LVEF on multigated acquisition blood pool scans (MUGA). ImagenSPECT™ 3.0 is used to quantitate the uptake of 99mTc pyrophosphate in early and late planar and SPECT studies.
The ImagenSPECT™ 3.0 system is designed to take nuclear medicine data from commercially available SPECT systems and process the data into a format that can be visualized by a separate computer program or workstation.
In addition, quarter-counts, half dose and/or half-time scans can be reconstructed with ImagenSPECT™ 3.0 using resolution recovery, iterative reconstruction and is equivalent to the predicate ImagenSPECT™ (k152503) using half-counts and full counts (full-time scan, half dose/ half-time, full dose).
CARDIOVASCULAR IMAGING TECHNOLOGIES L.L.C.
3.0
In Commercial Distribution
- 00862611000349 ()
- SPECT system application software
- Radiology DICOM image processing application software
The ImagenSPECT™ system is a software application that provides a processing environment for the analysis and display of cardiac SPECT images. The results of this processing may be used in determining the presence of cardiac diseases. Data for ImagenSPECT is derived from a nuclear medicine gamma camera. The resulting datasets may be either planar or 3D tomograms of patient anatomy.
CARDIOVASCULAR IMAGING TECHNOLOGIES L.L.C.
2.0
In Commercial Distribution
- 00862611000301 ()
- SPECT system application software
- Radiology DICOM image processing application software
BeamSite™ is a camera system that enables live visualization of the treatment beam on a patient during radiotherapy. It is an optically based system that is non-patient contacting and produces no radiation. When the treatment beam is on, BeamSite captures images of Cherenkov light emitted from the patient’s skin during radiotherapy to provide an optical map of the treatment beam on the patient. When the treatment beam is off, the system provided continuous background images of the treatment area under ambient light illumination. The BeamSite system consists of a camera, a workstation with preinstalled BeamSite software, and a monitor to be used by clinical radiotherapy teams to a) visually observe the patient and the Cherenkov light emitted from irradiated surface anatomy, and b) review the treatment images, if necessary.
Doseoptics LLC
BeamSite
In Commercial Distribution
- 00860009184503 ()
- Radiation therapy software
- Radiation therapy system workstation, multi-purpose
InferRead Lung CT.AI is comprised of computer assisted reading tools designed to aid the radiologist in the detection of pulmonary nodules during the review of CT examinations of the chest.
Infervision Medical Technology Co., Ltd
5.0.2.5
In Commercial Distribution
- 00850003095042 ()
- X-ray image interpretive software
- Diagnostic x-ray digital imaging system workstation
InferRead CT Stroke.AI is a radiological computer aided triage and notification software for use in the analysis of non-enhanced head CT images. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging suspected positive findings of intracranial hemorrhage (ICH).
Infervision US Inc
1.1.0.0
In Commercial Distribution
- 00850003095011 ()
- Diagnostic x-ray digital imaging system workstation
- X-ray image interpretive software
Computer assisted reading tools designed to aid the radiologist in the detection of pulmonary nodules during review of CT examinations of the chest.
Infervision US Inc
2.1.2.1
In Commercial Distribution
- 00850003095004 ()
- X-ray image interpretive software
- Diagnostic x-ray digital imaging system workstation
Cassette Printer with AutoLoader
SAKURA FINETEK U.S.A., INC.
9020
In Commercial Distribution
- 00615233082374 ()
9020
- Cell morphology analyser IVD, automated/semi-automated
- Computed radiography digital imaging scanner
Brand Name: PlaDuo PRO System (PlaDuo System)
Model: PlaDuo PRO System
shenb Co., Ltd.
PlaDuo PRO System
In Commercial Distribution
- 08800017101422 ()
- Nitrogen plasma skin surface treatment system
- Argon-enhanced electrosurgical system gas delivery unit
No Description
shenb Co., Ltd.
PlaDuo
In Commercial Distribution
- 08800017101118 ()
- Nitrogen plasma skin surface treatment system
- Argon-enhanced electrosurgical system gas delivery unit
TigerView software version 8.4.1
TELEVERE SYSTEMS, LLC
8.4.1
In Commercial Distribution
- 00851800007108 ()
TigerView 8.4.1
- Basic diagnostic x-ray system application software
- Camera application software
- Multidisciplinary medical image management software
- General-purpose dental x-ray system application software
- Radiological PACS software
TigerView software version 8.2
TELEVERE SYSTEMS, LLC
8.2
In Commercial Distribution
- 00851800007085 ()
TigerView 8.2
- Radiological PACS software
- General-purpose dental x-ray system application software
- Multidisciplinary medical image management software
- Camera application software
- Basic diagnostic x-ray system application software
ExamVue PACS version 1.1 Build 81
TELEVERE SYSTEMS, LLC
1.1 Build 81
In Commercial Distribution
- 00851800007078 ()
ExamVue PACS 1.1 Build 81
- Radiological PACS software
- General-purpose dental x-ray system application software
- Multidisciplinary medical image management software
- Camera application software
- Basic diagnostic x-ray system application software
TigerView software version 8.3
TELEVERE SYSTEMS, LLC
8.3
In Commercial Distribution
- 00851800007061 ()
TigerView 8.3
- Basic diagnostic x-ray system application software
- Camera application software
- Multidisciplinary medical image management software
- General-purpose dental x-ray system application software
- Radiological PACS software
TigerView Pro software version 7.7.3
TELEVERE SYSTEMS, LLC
7.7.3
In Commercial Distribution
- 00851800007023 ()
TigerView Pro 7.7.3
- Radiological PACS software
- General-purpose dental x-ray system application software
- Multidisciplinary medical image management software
- Camera application software
- Basic diagnostic x-ray system application software
TigerView 8.1 software Build 81
TELEVERE SYSTEMS, LLC
8.1 Build 81
In Commercial Distribution
- 00851800007016 ()
TigerView 8.1 Build 81
- Basic diagnostic x-ray system application software
- Camera application software
- Multidisciplinary medical image management software
- General-purpose dental x-ray system application software
- Radiological PACS software
TigerView Pro software version 7.7.13
TELEVERE SYSTEMS, LLC
7.7.13
In Commercial Distribution
- 00851800007009 ()
TigerView Pro 7.7.13
- Radiological PACS software
- General-purpose dental x-ray system application software
- Multidisciplinary medical image management software
- Camera application software
- Basic diagnostic x-ray system application software
ImmersiveTouch4 is a hardware accessory to ImmersiveTouch simulator. It supports ImmersiveTouch simulator to function as pre-operative software for simulating and evaluating surgical treatment options.
IMMERSIVETOUCH, INC.
ImmersiveTouch4
In Commercial Distribution
- B940IVZBKIT0 ()
- Portable computer
Bioness Integrated Therapy System Version 3.0, Hardware It - 55" Display, BITS Software Kit, BITS PC Kit, BITS Balance Accessory Kit, and BITS Balance Platform Kit
BIONESS INC.
BITS-3055
In Commercial Distribution
- 00815962020610 ()
- Perceptual-coordination assistive training device
HDi System Overpack, with ACIST Connect, JAPAN p/n 801081-001
Contents: System Console, Linear Translation System (LTS), Patient Interface Module (PIM), Power Supply, ACI Hardware
ACIST MEDICAL SYSTEMS, INC.
016323
Not in Commercial Distribution
- 40841716102057 ()
- Cardiovascular ultrasound imaging system
ANNE Limb is a pulse oximeter intended for continuous monitoring of SpO2, pulse rate, and skin temperature.
Sibel Health Inc.
810-00013
In Commercial Distribution
- 00860004541752 ()
- Pulse oximeter
- Wearable multiple vital physiological parameter monitor
Pathway® CTS 1500
PROMETHEUS GROUP OF NEW HAMPSHIRE LIMITED, THE
CTS1500
In Commercial Distribution
- 00852423006028 ()
CTS1500
- Psychophysiological biofeedback system