SEARCH RESULTS FOR: (*Sandwhich Panel Machine*)(8781 results)
The G5® ALC™ Over-The-Shoulder Massage Machine produces a non-invasive therapy treatment for skin, scalp, tissue, muscles, lymph nodes and the circulatory system. A wide array of applicators combine with the ALC™ unit to provide aesthetic services such as cellulite reduction, exfoliation, lymphatic drainage, body contouring, skin toning and muscle relaxation. Comes complete with caster stand, accessory tray, and applicators. Unit Advantages: • Versatility: Pole, Table Top
• Portability: In-mold handle and smooth casters to easily move from room to room • CPS Indicator on Control Panel • Extra tall stand so cable can hang over the
operator’s shoulder for ease of use
GENERAL PHYSIOTHERAPY INC
ALC 120 G5
In Commercial Distribution
- 00746980001582 ()
- Weight: 38 Pound
ALC 120 G5
- Freestanding electric massager
The integrated Backup NO delivery system is a completely independent backup NO generating system that is separate from the main delivery system; it has its own NO generator and gas flow delivery system. Backup NO flow can be delivered to one of two different locations by using the System Selector switch located on the front panel of the LungFit PH system.
When the Selector Switch is turned to “Bagging System” position, the backup NO module turns on and delivers 1 L/min of 220 ppm of NO through a separate internal NO2 filter to the Bagging System connector on the front panel of the LungFit PH system. The Bagging System connector has two tubing fittings: one for connecting to an air/oxygen source through oxygen tubing or equivalent to provide an external flow of air/oxygen and the other to connect to a manual resuscitator for manually ventilating a patient. The 1 L/min NO flow from the backup NO module is added to this air/oxygen flow which dilutes the NO concentration down to therapeutic levels. Final NO concentration will depend on the amount of external flow added; for example, a flow of 10 L/min will provide 20 ppm of NO to the patient.
Beyond Air, Inc.
90005
In Commercial Distribution
- B882900051 ()
- B882900050 ()
- B882900052 ()
- Nitric oxide delivery unit, system-based
The ProxiDiagnost N90 is a multi-functional general Radiography/ Fluoroscopy (R/F) system and includes
• Footrest
• Hand Grips
Radiation Protection Accessories
• Flexible Radiation Protection Apron
• Front Radiation Protection Apron
Additional Accessories (Optional)
• Monitor Trolley
• Monitor Ceiling Suspension
• Parking Frame for Accessories
• Shoulder Support
• Side bar
• Compression Belt
• Adjustable Lateral Cassette Holder
• Leg Supports
• Infusion Bottle Holder
• Arm Support for Catheterization
• Ankle Clamps
• Overhead Hand Grip
• Adult Headrest
• Mattress
• Rotatable Stool for Footrest
• Pediatric Micturition Set
• Stretch Grip for Wall Stand
• Bar Code Scanner
• Patient Support
• Stitching Ruler
Accessories for the SkyPlate Detector (Optional)
• Mobile Detector Holder
• Detector Holder Patient Bed
• Portable Panel Protector
• Detector Handle
• WPD Bags
• Grids for SkyPlate Detector large
Philips Medical Systems DMC GmbH
706110
In Commercial Distribution
- 00884838103221 ()
- Stationary general-purpose fluoroscopic x-ray system, digital
Radiography 7000 M digital mobile is a new motorized mobile x-ray system that includes:
1. Base Unit ( Sedecal Mobile X-ray system - SM-IV, cleared under K232185 August 21, 2023)
2. SkyPlate Family of detectors (Wireless Portable Detectors) and their accessories
3. Eleva WorkSpot
In addition, the following accessories can be used together with the system - Raidography 7000 M:
- Detector Holder f. Patient Bed
- Grid Landsc. SkyPlateE Large
- Grid Landscape SkyPlate Large
- Grid Portr. SkyPlate E Large
- Grid Portrait SkyPlate Large
- Grid Portrait SkyPlate Small
- Handle for Skyplate Large
- Portable Panel Protector
- Wireless Detect. Mobile Holder
- Set of 50 WPD Hygienic Bags (large)
- Set of 50 WPD Hygienic Bags (small)
Philips Medical Systems DMC GmbH
712010
In Commercial Distribution
- 00884838115521 ()
- Mobile basic diagnostic x-ray system, digital
The Precision CRF is a multi-functional general Radiography/ Fluoroscopy (R/F) system and includes
• Footrest
• Hand Grips
Radiation Protection Accessories
• Flexible Radiation Protection Apron
• Front Radiation Protection Apron
Additional Accessories (Optional)
• Monitor Trolley
• Monitor Ceiling Suspension
• Parking Frame for Accessories
• Shoulder Support
• Side bar
• Compression Belt
• Adjustable Lateral Cassette Holder
• Leg Supports
• Infusion Bottle Holder
• Arm Support for Catheterization
• Ankle Clamps
• Overhead Hand Grip
• Adult Headrest
• Mattress
• Rotatable Stool for Footrest
• Pediatric Micturition Set
• Stretch Grip for Wall Stand
• Bar Code Scanner
• Patient Support
• Stitching Ruler
Accessories for the SkyPlate Detector (Optional)
• Mobile Detector Holder
• Detector Holder Patient Bed
• Portable Panel Protector
• Detector Handle
• WPD Bags
• Grids for SkyPlate Detector large
Philips Medical Systems DMC GmbH
706400
In Commercial Distribution
- 00884838110588 ()
- Stationary general-purpose fluoroscopic x-ray system, digital
The Piccolo® Kidney Check , used with the Piccolo Xpress chemistry analyzer, is intended to be used for the in vitro quantitative determination of creatinine and blood urea nitrogen (BUN) in heparinized whole blood, heparinized plasma, or serum in a clinical laboratory setting or point-of-care location.
The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.
ABAXIS, INC.
400-0033
In Commercial Distribution
- EABA40000331 ()
- EABA40000330 ()
400-0033
- Urea IVD, reagent
- Creatinine IVD, reagent
MOCACuff (HL168KF) uses the oscillometric method to automatically measure systolic and diastolic blood pressure as well as heart rate. The measurement position is at human being’s wrist. All values can be read out in one LD panel. The device is designed for home use and recommended for use by adults aged 18 years and older with wrist circumference ranging approx. 5.3~7.7 inch.
The user is able to set the personal target value and the device will flash the value when the measured blood pressure value exceeds the target one. Further, HL168KF feature a built-in Bluetooth Data Transmission function, which enables the device automatically transmit measuring results to paired Bluetooth device after measurement.
MOCACARE CORP.
White (HL168KF)
In Commercial Distribution
- 00850842006063 ()
- Automatic-inflation electronic sphygmomanometer, portable, arm/wrist
The IOPS (Intra-Operative Positioning System) is intended for the evaluation of vascular anatomy as captured using 3D modeling from previously acquired scan data. It is intended for real-time tip positioning and navigation using sensor-equipped, compatible catheters and guidewires used in endovascular interventions in the descending aorta. After the patient is placed on the OR table, a cone beam CT (CBCT) is acquired using fluoroscopy with a flat panel detector (FPD). The scan is uploaded to the hospital’s PACS. The CBCT is registered to the initial CT using the IOPS software and the 3D renderings. The system is indicated for use as an adjunct to fluoroscopy. The IOPS does not make a diagnosis.
Centerline Biomedical, Inc.
SW-1
In Commercial Distribution
- 00843152104000 ()
SW-1
- Electromagnetic surgical navigation device tracking system
The IOPS (Intra-Operative Positioning System) is intended for the evaluation of vascular anatomy as captured using 3D modeling from previously acquired scan data. It is intended for real-time tip positioning and navigation using sensor-equipped, compatible catheters and guidewires used in endovascular interventions in the descending aorta. After the patient is placed on the OR table, a cone beam CT (CBCT) is acquired using fluoroscopy with a flat panel detector (FPD). The scan is uploaded to the hospital’s PACS. The CBCT is registered to the initial CT using the IOPS software and the 3D renderings. The system is indicated for use as an adjunct to fluoroscopy. The IOPS does not make a diagnosis.
Centerline Biomedical, Inc.
MC-1
In Commercial Distribution
- 00843152100002 ()
MC-1
- Electromagnetic surgical navigation device tracking system
UNIT CART PREMIUM-ELEC. 100-120VAC Universal device cart with reinforced bridge for mounting swivel arms, incl. rear panel and integrated cable duct. 3 shelf units (width 370 mm), 2 of which continuously adjustable. 4 double casters, 2 of which with dual-function locking (directional locking/freewheeling/full locking), 2 electrically conductive casters. Interfaces for mounting swivel arms and attaching comprehensive accessories. color: white, RAL 9016, side profiles made of aluminum. dimensions (WxHxD): 720 x 1,518 x 700 mm. Cart including PREMIUM ELECTRICS 100-120V, consisting of: basic housing (premium version) with integrated isolating transformer 100- 120V, insulation monitoring unit and shutdown module, socket strip with main switch module, insulation monitor display and 12 sockets, 6 device connection cables.
Richard Wolf GmbH
32116013
In Commercial Distribution
- 04055207025024 ()
32116013
- Medical device integration rack