Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

EvB Push Button ESU Pencil - 2.5'' Stainless Blade, No Holster, Smoke Pencil, 10'' Cable
MEDIMAX TECH INC.
EvB Push Button ESU Pencil
In Commercial Distribution

  • 20817325020736 ()
  • 10817325020739 ()
  • 00817325020732 ()


  • Open-surgery electrosurgical handpiece/electrode, monopolar, reusable
  • Surgical plume evacuation system
microTargeting Frame Kit D.ZAP/Lead Insertion, 1x, Sterile, for use with mT Drive or STar Drive. Contains: 34685L: Single D.ZAP Electrode. 66-DA-SD: Drape Sleeve. 66-EL-LP: Patient Lead for LP+. 66-IT-05P: Single Insertion Tube Set.
FHC, INC.
KT-FPK-S20-00508
In Commercial Distribution

  • 00873263005088 ()
KT-FPK-S20

  • Depth electrode
  • Neurological stereotactic surgery system
  • Intracerebral cannula, implantable
microTargeting Platform Procedure Consumables Kit, 1x, sterile, for use with mT or STar Drive, mT Platform and Guideline 4000 LP+. Contains: 44975L: D.ZAP Tungsten Differential Electrode - - 220.72mm electrode length, 10mm differential, 205.72mm protective tube length, DZAP(L) 1Meg, 0.55mm od. 66-DA-SD: Sterile Drape Sleeve for motor 66-EL-LP: Patient Lead for Guideline 4000 LP+ 66-IT-03P: Sterile Single Insertion Tube Set - IT(MP1) - 184.1mm tube length, 1.83mm od, 1.6mm id with Stylet PT(MP1) - Diameter reduction tube 0.58mm id
FHC, INC.
KT-PPK-S-00366
In Commercial Distribution

  • 00873263003664 ()
KT-PPK-S

  • Depth electrode
  • Patient surgical drape, single-use
  • Intracerebral cannula, implantable
microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable. Contains: IT(BP2): Insertion Tube. 2x MTDWLN(BP)(BP7): microTargeting Electrode. PT(BP2): Protective Tube. Sterile Drape Sleeve for microTargeting motor FC1020 Electrode Lead Individual Specifications: IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar). MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L) PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID OD: 0.77mm
FHC, INC.
KTF1001-00133
Not in Commercial Distribution

  • 00873263001332 ()
KTF1001

  • Patient surgical drape, single-use
  • Intracerebral cannula, implantable
  • Depth electrode
microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable. Contains: IT(BP2): Insertion Tube. 2x MTDWLN(BP)(BP7): microTargeting Electrode. PT(BP2): Protective Tube. Sterile Drape Sleeve for microTargeting motor FC1020 Electrode Lead Individual Specifications: IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar). MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L) PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID OD: 0.77mm
FHC, INC.
KTF1001-00757
In Commercial Distribution

  • 00873263007570 ()
KTF1001

  • Depth electrode
  • Patient surgical drape, single-use
  • Intracerebral cannula, nonimplantable, single-use
primaLOK SP 18mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0118-00
In Commercial Distribution

  • 00813210021778 ()

  • Height: 18 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 15mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as ack pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0115-00
In Commercial Distribution

  • 00813210021761 ()

  • Height: 15 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 12mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as ack pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0112-00
In Commercial Distribution

  • 00813210021754 ()

  • Height: 12 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 10mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as ack pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0110-00
In Commercial Distribution

  • 00813210021747 ()

  • Height: 10 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 8mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0108-00
In Commercial Distribution

  • 00813210021730 ()

  • Height: 8 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 6mm Implant Assembly, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0106-00
In Commercial Distribution

  • 00813210021723 ()

  • Height: 6 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
primaLOK SP 28mm Medium Boxless Implant, Sterile The Wenzel Spine primaLOK SP Interspinous Fusion System is a posterior, nonpedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). it is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e. fracture or dislocation), and/or tumor. The primaLOK SP Interspinous Fusion System is intended for use at one level with bone graft material and not intended for stand-alone use.
Wenzel Spine, Inc.
800-0828-00
In Commercial Distribution

  • 00813210021785 ()

  • Width: 28 Millimeter


  • Orthopaedic fixation plate kit, non-bioabsorbable, non-antimicrobial
16mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD8
In Commercial Distribution

  • 1199028 ()
  • M364119902FD80 ()

  • Outer Diameter: 16 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
14mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD5
In Commercial Distribution

  • 1199025 ()
  • M364119902FD50 ()

  • Outer Diameter: 14 Millimeter
  • Length: 21 Millimeter


  • Metallic spinal interbody fusion cage
10mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation
MEDICAL DESIGNS LLC
11-9902-FD2
In Commercial Distribution

  • 1199022 ()
  • M364119902FD20 ()

  • Outer Diameter: 10 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
18mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD9
In Commercial Distribution

  • 1199029 ()
  • M364119902FD90 ()

  • Outer Diameter: 18 Millimeter
  • Length: 21 Millimeter


  • Metallic spinal interbody fusion cage
16mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD7
In Commercial Distribution

  • M364119902FD70 ()


  • Metallic spinal interbody fusion cage
14mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD6
In Commercial Distribution

  • 1199026 ()
  • M364119902FD60 ()

  • Outer Diameter: 14 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
12mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD4
In Commercial Distribution

  • 1199024 ()
  • M364119902FD40 ()

  • Outer Diameter: 12 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
12mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD3
In Commercial Distribution

  • 1199023 ()
  • M364119902FD30 ()

  • Outer Diameter: 12 Millimeter
  • Length: 21 Millimeter


  • Metallic spinal interbody fusion cage
18mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD10
In Commercial Distribution

  • 11990210 ()
  • M364119902FD100 ()

  • Outer Diameter: 18 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
10mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD1
In Commercial Distribution

  • M364119902FD10 ()
  • 1199021 ()

  • Length: 21 Millimeter
  • Outer Diameter: 10 Millimeter


  • Metallic spinal interbody fusion cage
primaLOK FF 45mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1145-00
In Commercial Distribution

  • 00813210021990 ()

  • Length: 45 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 40mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1140-00
In Commercial Distribution

  • 00813210021983 ()

  • Length: 40 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 35mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1135-00
In Commercial Distribution

  • 00813210021976 ()

  • Length: 35 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 30mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1130-00
In Commercial Distribution

  • 00813210021969 ()

  • Length: 30 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 25mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1125-00
In Commercial Distribution

  • 00813210021952 ()

  • Length: 25 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-15-24-00
In Commercial Distribution

  • 00813210020023 ()

  • Length: 24 Millimeter
  • Outer Diameter: 15 Millimeter


  • Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-13-24-00
In Commercial Distribution

  • 00813210020016 ()

  • Length: 24 Millimeter
  • Outer Diameter: 13 Millimeter


  • Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-11-24-00
In Commercial Distribution

  • 00813210020009 ()

  • Length: 24 Millimeter
  • Outer Diameter: 11 Millimeter


  • Metallic spinal interbody fusion cage