SEARCH RESULTS FOR: 【溦信88931766】推特主播onlyfans【老主播2【6.36gb18v】最全所有视频资源全部作品合集.aqc(4948 results)
The Final Fit software receives the measured data from the Refractive Power/Corneal Analyzer OPD-Scan Model ARK-10000 via floppy disk etc. Then the Final Fit software performs a simulation of postoperative corneal shape and generates shot data using the imported data that was measured by the ARK-10000 and amounts of correction that are entered.
The Final Fit software has two major functions:
1.Generating shot data to be used with the EC-5000 based on the measured data of the ARK-10000
2.Comparing postoperative data measured by ARK-10000 with the preoperative or target data (Simulated data just before generating shot data)
NIDEK CO.,LTD.
1.11US
In Commercial Distribution
- 04987669100035 ()
- Ophthalmic excimer laser system
The Access Hybritech p2PSA assay is a paramagnetic particle, chemiluminescent immunoassay for the quantitative determination of [-2]proPSA antigen, an isoform of free PSA, in human serum using the Access Immunoassay Systems. Access Hybritech p2PSA is intended to be used in combination with Access Hybritech (total) PSA and Access Hybritech free PSA to calculate the Beckman Coulter Prostate Health Index (phi), an In Vitro Diagnostic Multivariate Index
Assay (IVDMIA). Beckman Coulter phi as calculated using the Access Hybritech assays is indicated for use as an aid in distinguishing prostate cancer from benign prostatic conditions, for prostate cancer detection in men aged 50 years and older with total PSA ≥ 4.0 to ≤ 10.0 ng/mL, and with digital rectal examination findings that are not suspicious for cancer. Prostatic biopsy is required for diagnosis of cancer.
Beckman Coulter, Inc.
B03704
In Commercial Distribution
- H628B037041 ()
B03704
- Free (unbound) prostate specific antigen (fPSA) IVD, kit, chemiluminescent immunoassay
Paragon CRT® Contact Lenses are manufactured from Paragon HDS® (paflufocon B). The lenses are designed to have congruent anterior and posterior surfaces each consisting of three zones: The central spherical zone, A mathematically designed sigmoidal corneal proximity “Return Zone” and A non-curving “Landing Zone”. Paragon CRT® Contact Lenses for Corneal Refractive Therapy are to be worn overnight with removal during all or part of each following day. The material is thermoset fluorosilicone acrylate copolymer derived primarily from siloxane acrylate, trifluoroethyl methacrylate and methylmethacrylate with a water content of less than 1%. These contact lenses for Corneal Refractive Therapy are available as lathe cut firm contact lenses with blue, violet and green tints. The tinted lenses depending on the tint color contain D&C Green No. 6, D&C Violet No. 2 and Perox Yellow No. 9 (4-[(2,4-dimethylphenyl)azo]-2,4-dihydro-5-methyl-2-phenyl-3H-pyrazol-3-one). These products may be plasma treated.
Paragon Vision Sciences, Inc.
Paragon CRT
In Commercial Distribution
- B22217 ()
- Orthokeratology contact lens
The Cross-Seal Device is composed of a Catheter, Suture Delivery System, and Handle.
The Cross-Seal Device tracks over a standard 0.038” or 0.035” (minimum length 130 cm) guidewire. A hemostasis valve located in the middle of the CATHETER limits blood flow from the GUIDEWIRE PORT through the CATHETER with or without the guidewire in place. The SUTURE DELIVERY SYSTEM contains NEEDLES, LOCATOR WINGS, and the NEEDLE BARREL that control suture placement around the arteriotomy. The HANDLE contains the SLIDER, BLEEDING INDICATOR, PLUNGER, RESET 1 BUTTON (SLIDER RETRACTOR), and RESET 2 BUTTON (LOCATOR WINGS RETRACTOR). The SLIDER triggers a mechanism that opens the LOCATOR WINGS and creates a sandwich configuration to stabilize the delivery system within the vessel wall. The BLEEDING INDICATOR connects to a lumen that has an intraluminal port positioned at the distal end of the Suture Delivery System to allow bleeding back to ensure Suture Delivery System is positioned properly in the femoral artery. The NEEDLE BARREL keeps the Cross-Seal Device from moving deeper inside the vessel, stabilizes the device once the LOCATOR WINGS are opened and retrieves the disengaged suture-carried NEEDLES. The PLUNGER triggers the NEEDLES to deploy sutures and simultaneously close the LOCATOR WINGS. The GUIDEWIRE GUIDE is the feature at distal handle portion which allows physician to practice coaxial insertion of device along guidewire if necessary.
MEDEON BIODESIGN, INC.
002
In Commercial Distribution
- 04719872920359 ()
- 04719872920366 ()
- 04719872920373 ()
002
- Polyolefin/fluoropolymer suture, monofilament
The On-X® Prosthetic Heart Valve is a bileaflet mechanical heart valve, which consists of an orifice housing and two leaflets. The orifice inflow area has a flared inlet designed to reduce flow turbulence, and the outflow rim consists of leaflet guards designed to protect the leaflets while in the closed position. The leaflets rotate around tabs located within the inner circumference of the orifice ring. In the closed position, each leaflet forms a nominal angle of 40º relative to the plane of the orifice. In the open position, the plane of each leaflet forms a nominal angle of 90deg relative to the plane of the orifice. The leaflets have a travel arc of 50deg to the closed position.
The orifice, or housing, is composed of a graphite substrate coated with On-X® Carbon, a pure unalloyed form of pyrolytic carbon. The leaflets consist of On-X® Carbon deposited on a graphite substrate, which is impregnated with 10 weight% tungsten to provide radiopacity.
The sewing cuff is constructed of polytetrafluoroethylene (PTFE) fabric mounted on the orifice using titanium retaining rings and 5-0 suture material. This form of sewing cuff attachment to the orifice allows for rotation of the sewing cuff in situ during implantation. Orientation reference marks are provided on the sewing cuff for valve orientation.
The On-X® Prosthetic Heart Valve is available in 3 aortic and 2 mitral sewing cuff configurations. Aortic configurations are available in sizes 19, 21, 23, 25, and 27/29 mm. The standard mitral cuff is available in sizes 23, 25, 27/29 and 31/33, while the Conform-X® mitral cuff is available in size 25/33 only.
Further detail for the On-X prosthetic heart valve is described in the Summary of Safety and Effectiveness documents for the On-X heart valves: http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037b.pdf (aortic), and http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037S001b.pdf (mitral).
ON-X LIFE TECHNOLOGIES, INC.
ONXAN-23
In Commercial Distribution
- 00851788001617 ()
- Outer Diameter: 23 Millimeter
- Aortic bi-leaflet mechanical heart valve prosthesis
The On-X® Prosthetic Heart Valve is a bileaflet mechanical heart valve, which consists of an orifice housing and two leaflets. The orifice inflow area has a flared inlet designed to reduce flow turbulence, and the outflow rim consists of leaflet guards designed to protect the leaflets while in the closed position. The leaflets rotate around tabs located within the inner circumference of the orifice ring. In the closed position, each leaflet forms a nominal angle of 40º relative to the plane of the orifice. In the open position, the plane of each leaflet forms a nominal angle of 90deg relative to the plane of the orifice. The leaflets have a travel arc of 50deg to the closed position.
The orifice, or housing, is composed of a graphite substrate coated with On-X® Carbon, a pure unalloyed form of pyrolytic carbon. The leaflets consist of On-X® Carbon deposited on a graphite substrate, which is impregnated with 10 weight% tungsten to provide radiopacity.
The sewing cuff is constructed of polytetrafluoroethylene (PTFE) fabric mounted on the orifice using titanium retaining rings and 5-0 suture material. This form of sewing cuff attachment to the orifice allows for rotation of the sewing cuff in situ during implantation. Orientation reference marks are provided on the sewing cuff for valve orientation.
The On-X® Prosthetic Heart Valve is available in 3 aortic and 2 mitral sewing cuff configurations. Aortic configurations are available in sizes 19, 21, 23, 25, and 27/29 mm. The standard mitral cuff is available in sizes 23, 25, 27/29 and 31/33, while the Conform-X® mitral cuff is available in size 25/33 only.
Further detail for the On-X prosthetic heart valve is described in the Summary of Safety and Effectiveness documents for the On-X heart valves: http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037b.pdf (aortic), and http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037S001b.pdf (mitral).
ON-X LIFE TECHNOLOGIES, INC.
ONXAN-21
In Commercial Distribution
- 00851788001600 ()
- Outer Diameter: 21 Millimeter
- Aortic bi-leaflet mechanical heart valve prosthesis
The On-X® Prosthetic Heart Valve is a bileaflet mechanical heart valve, which consists of an orifice housing and two leaflets. The orifice inflow area has a flared inlet designed to reduce flow turbulence, and the outflow rim consists of leaflet guards designed to protect the leaflets while in the closed position. The leaflets rotate around tabs located within the inner circumference of the orifice ring. In the closed position, each leaflet forms a nominal angle of 40º relative to the plane of the orifice. In the open position, the plane of each leaflet forms a nominal angle of 90deg relative to the plane of the orifice. The leaflets have a travel arc of 50deg to the closed position.
The orifice, or housing, is composed of a graphite substrate coated with On-X® Carbon, a pure unalloyed form of pyrolytic carbon. The leaflets consist of On-X® Carbon deposited on a graphite substrate, which is impregnated with 10 weight% tungsten to provide radiopacity.
The sewing cuff is constructed of polytetrafluoroethylene (PTFE) fabric mounted on the orifice using titanium retaining rings and 5-0 suture material. This form of sewing cuff attachment to the orifice allows for rotation of the sewing cuff in situ during implantation. Orientation reference marks are provided on the sewing cuff for valve orientation.
The On-X® Prosthetic Heart Valve is available in 3 aortic and 2 mitral sewing cuff configurations. Aortic configurations are available in sizes 19, 21, 23, 25, and 27/29 mm. The standard mitral cuff is available in sizes 23, 25, 27/29 and 31/33, while the Conform-X® mitral cuff is available in size 25/33 only.
Further detail for the On-X prosthetic heart valve is described in the Summary of Safety and Effectiveness documents for the On-X heart valves: http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037b.pdf (aortic), and http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037S001b.pdf (mitral).
ON-X LIFE TECHNOLOGIES, INC.
ONXAN-19
In Commercial Distribution
- 00851788001594 ()
- Outer Diameter: 19 Millimeter
- Aortic bi-leaflet mechanical heart valve prosthesis
The On-X® Prosthetic Heart Valve is a bileaflet mechanical heart valve, which consists of an orifice housing and two leaflets. The orifice inflow area has a flared inlet designed to reduce flow turbulence, and the outflow rim consists of leaflet guards designed to protect the leaflets while in the closed position. The leaflets rotate around tabs located within the inner circumference of the orifice ring. In the closed position, each leaflet forms a nominal angle of 40º relative to the plane of the orifice. In the open position, the plane of each leaflet forms a nominal angle of 90deg relative to the plane of the orifice. The leaflets have a travel arc of 50deg to the closed position.
The orifice, or housing, is composed of a graphite substrate coated with On-X® Carbon, a pure unalloyed form of pyrolytic carbon. The leaflets consist of On-X® Carbon deposited on a graphite substrate, which is impregnated with 10 weight% tungsten to provide radiopacity.
The sewing cuff is constructed of polytetrafluoroethylene (PTFE) fabric mounted on the orifice using titanium retaining rings and 5-0 suture material. This form of sewing cuff attachment to the orifice allows for rotation of the sewing cuff in situ during implantation. Orientation reference marks are provided on the sewing cuff for valve orientation.
The On-X® Prosthetic Heart Valve is available in 3 aortic and 2 mitral sewing cuff configurations. Aortic configurations are available in sizes 19, 21, 23, 25, and 27/29 mm. The standard mitral cuff is available in sizes 23, 25, 27/29 and 31/33, while the Conform-X® mitral cuff is available in size 25/33 only.
Further detail for the On-X prosthetic heart valve is described in the Summary of Safety and Effectiveness documents for the On-X heart valves: http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037b.pdf (aortic), and http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037S001b.pdf (mitral).
ON-X LIFE TECHNOLOGIES, INC.
ONXACE-23
In Commercial Distribution
- 00851788001464 ()
- Outer Diameter: 23 Millimeter
- Aortic bi-leaflet mechanical heart valve prosthesis
The On-X® Prosthetic Heart Valve is a bileaflet mechanical heart valve, which consists of an orifice housing and two leaflets. The orifice inflow area has a flared inlet designed to reduce flow turbulence, and the outflow rim consists of leaflet guards designed to protect the leaflets while in the closed position. The leaflets rotate around tabs located within the inner circumference of the orifice ring. In the closed position, each leaflet forms a nominal angle of 40º relative to the plane of the orifice. In the open position, the plane of each leaflet forms a nominal angle of 90deg relative to the plane of the orifice. The leaflets have a travel arc of 50deg to the closed position.
The orifice, or housing, is composed of a graphite substrate coated with On-X® Carbon, a pure unalloyed form of pyrolytic carbon. The leaflets consist of On-X® Carbon deposited on a graphite substrate, which is impregnated with 10 weight% tungsten to provide radiopacity.
The sewing cuff is constructed of polytetrafluoroethylene (PTFE) fabric mounted on the orifice using titanium retaining rings and 5-0 suture material. This form of sewing cuff attachment to the orifice allows for rotation of the sewing cuff in situ during implantation. Orientation reference marks are provided on the sewing cuff for valve orientation.
The On-X® Prosthetic Heart Valve is available in 3 aortic and 2 mitral sewing cuff configurations. Aortic configurations are available in sizes 19, 21, 23, 25, and 27/29 mm. The standard mitral cuff is available in sizes 23, 25, 27/29 and 31/33, while the Conform-X® mitral cuff is available in size 25/33 only.
Further detail for the On-X prosthetic heart valve is described in the Summary of Safety and Effectiveness documents for the On-X heart valves: http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037b.pdf (aortic), and http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037S001b.pdf (mitral).
ON-X LIFE TECHNOLOGIES, INC.
ONXANE-27/29
In Commercial Distribution
- 00851788001686 ()
- Outer Diameter: 29 Millimeter
- Aortic bi-leaflet mechanical heart valve prosthesis
The On-X® Prosthetic Heart Valve is a bileaflet mechanical heart valve, which consists of an orifice housing and two leaflets. The orifice inflow area has a flared inlet designed to reduce flow turbulence, and the outflow rim consists of leaflet guards designed to protect the leaflets while in the closed position. The leaflets rotate around tabs located within the inner circumference of the orifice ring. In the closed position, each leaflet forms a nominal angle of 40º relative to the plane of the orifice. In the open position, the plane of each leaflet forms a nominal angle of 90deg relative to the plane of the orifice. The leaflets have a travel arc of 50deg to the closed position.
The orifice, or housing, is composed of a graphite substrate coated with On-X® Carbon, a pure unalloyed form of pyrolytic carbon. The leaflets consist of On-X® Carbon deposited on a graphite substrate, which is impregnated with 10 weight% tungsten to provide radiopacity.
The sewing cuff is constructed of polytetrafluoroethylene (PTFE) fabric mounted on the orifice using titanium retaining rings and 5-0 suture material. This form of sewing cuff attachment to the orifice allows for rotation of the sewing cuff in situ during implantation. Orientation reference marks are provided on the sewing cuff for valve orientation.
The On-X® Prosthetic Heart Valve is available in 3 aortic and 2 mitral sewing cuff configurations. Aortic configurations are available in sizes 19, 21, 23, 25, and 27/29 mm. The standard mitral cuff is available in sizes 23, 25, 27/29 and 31/33, while the Conform-X® mitral cuff is available in size 25/33 only.
Further detail for the On-X prosthetic heart valve is described in the Summary of Safety and Effectiveness documents for the On-X heart valves: http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037b.pdf (aortic), and http://www.accessdata.fda.gov/cdrh_docs/pdf/P000037S001b.pdf (mitral).
ON-X LIFE TECHNOLOGIES, INC.
ONXANE-25
In Commercial Distribution
- 00851788001679 ()
- Outer Diameter: 25 Millimeter
- Aortic bi-leaflet mechanical heart valve prosthesis