Preci-Clix 1261 Starter Kit . kit contains . 2 Preci-Clix 1261 . 1 Clix Female Insertion Tool . 1 Preci-Clix/Ball Hex driver . 1 M2 Axial/Clix Mandrel
Preat Corporation
01K1261
In Commercial Distribution
- 00842092169261 ()
01K1261
- Resilient dental precision attachment
- Dental laboratory mandrel
- Surgical screwdriver, single-use
- Dental precision attachment fitting/adjustment tool
Preci-Clix 1276 Starter Kit . kit contains . 2 Preci-Clix 1276 . 1 Clix Female Insertion Tool . 1 Ceka Site . 1 Green Revax/Clix Mandrel . 1 Preci-Clix/Ball Hex driver). 1 M2 Axial/Clix Mandrel
Preat Corporation
01K1276
In Commercial Distribution
- 00842092169124 ()
01K1276
- Resilient dental precision attachment
- Dental laboratory mandrel
- Surgical screwdriver, single-use
- Dental precision attachment fitting/adjustment tool
The Upstream™ GoBack (GB) Crossing Catheter is designed to address the needs of vascular interventionalists (Radiologists, Angiologists) and vascular surgeons when attempting to place a guidewire in the peripheral vasculature during endovascular procedures.
The Upstream™ GB Crossing Catheter is intended to be used in conjunction with a steerable guidewires to access discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires.
The Upstream GoBack Crossing Catheter have outer diameter of 4FRr (1.4mm) or 2.9Fr (0.96mm), accommodate 0.018” or 0.014” guidewires accordingly, and both diameters have effective length of 80cm or 120 cm.
UPSTREAM PERIPHERAL TECHNOLOGIES LTD
GB 603-US 014P 80L
Not in Commercial Distribution
- 07290017837239 ()
- Peripheral vascular intervention infusion catheter
The Upstream™ GoBack (GB) Crossing Catheter is designed to address the needs of vascular interventionalists (Radiologists, Angiologists) and vascular surgeons when attempting to place a guidewire in the peripheral vasculature during endovascular procedures.
The Upstream™ GB Crossing Catheter is intended to be used in conjunction with a steerable guidewires to access discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires.
The Upstream GoBack Crossing Catheter have outer diameter of 4FRr (1.4mm) or 2.9Fr (0.96mm), accommodate 0.018” or 0.014” guidewires accordingly, and both diameters have effective length of 80cm or 120 cm.
UPSTREAM PERIPHERAL TECHNOLOGIES LTD
GB 603-US 014P 120L
Not in Commercial Distribution
- 07290017837222 ()
- Peripheral vascular intervention infusion catheter
The Upstream™ GoBack (GB) Crossing Catheter is designed to address the needs of vascular interventionalists (Radiologists, Angiologists) and vascular surgeons when attempting to place a guidewire in the peripheral vasculature during endovascular procedures.
The Upstream™ GB Crossing Catheter is intended to be used in conjunction with a steerable guidewires to access discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires.
The Upstream GoBack Crossing Catheter have outer diameter of 4FRr (1.4mm) or 2.9Fr (0.96mm), accommodate 0.018” or 0.014” guidewires accordingly, and both diameters have effective length of 80cm or 120 cm.
UPSTREAM PERIPHERAL TECHNOLOGIES LTD
GB 600-US 018P 80L
Not in Commercial Distribution
- 07290017837116 ()
- Peripheral vascular intervention infusion catheter
The Upstream™ GoBack (GB) Crossing Catheter is designed to address the needs of vascular interventionalists (Radiologists, Angiologists) and vascular surgeons when attempting to place a guidewire in the peripheral vasculature during endovascular procedures.
The Upstream™ GB Crossing Catheter is intended to be used in conjunction with a steerable guidewires to access discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires.
The Upstream GoBack Crossing Catheter have outer diameter of 4FRr (1.4mm) or 2.9Fr (0.96mm), accommodate 0.018” or 0.014” guidewires accordingly, and both diameters have effective length of 80cm or 120 cm.
UPSTREAM PERIPHERAL TECHNOLOGIES LTD
GB 600-US 018P 120L
Not in Commercial Distribution
- 07290017837109 ()
- Peripheral vascular intervention infusion catheter
"The Wildcat CTO Catheter is intended to create a channel in totally occluded peripheral vessels. The device may also be used to faciliate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Wildcat Catheter is contraindicated for use in the iliac, coronary, cerebral or carotid vasculature.
The Wildcat Catheter is intended to be used to support steerable guidewires in accessing discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices. It may also be used to deliver saline or contrast.The Wildcat CTO Catheter is a 6F sheath and 0.035"" guidewire compatible over-the-wire device. It consists of a catheter shaft with a handle assembly at the porximal end and an atraumatic Distal Tip. A locking Luer connector at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only. At the Slider’s most proximal location, the Wedges are in the retracted position. At the mid-point location, the Wedges are deployed. Moving the slider distal from this point initiates deflection of the Distal Tip. The amount of tip deflection increases with distal movement of the slider. At the most distal location, the Wedges remain fully deployed and the Distal Tip is at maximum deflection. The deployment and retraction of the Wedges as well as the deflection of the Distal Tip is visible under fluoroscopic guidance.
AVINGER, INC.
W400
In Commercial Distribution
- 00851354004004 ()
W400
- Mechanical atherectomy system catheter, peripheral
"Kittycat 2 Catheter is a 5F sheath and 0.014” guidewire compatible over-the-wire device with a working length of 150 cm. It consists of a catheter shaft with handle assembly at the proximal end and an atraumatic Distal Tip. A locking Luer connecter at the proximal end provides entry to a lumen that supports and facilitates movement of a guidewire. The catheter has been irradiated for sterility and is intended for single use only.The Distal Tip houses Spiral Flutes and allows atraumatic advancement of the catheter through the vasculature. The pre-shaped Distal Tip is made of a malleable material and may be reshaped as needed by the user. The deflection of the Distal Tip is visible under fluoroscopic guidance.
The handle assembly consists of a Handle Body, Rotator, and Luer. The Handle Body controls rotational orientation of the catheter, including the flexible Distal Tip. The Rotator controls the rotational movement of the Distal Tip, independent of the catheter orientation. The Luer is provided at the proximal end to facilitate fluid flush and the entry/exit of the guidewire.
Kittycat 2 is intended to facilitate the intraluminal placement of conventional guidewires beyond stenotic lesions (including sub and chronic total occlusions) in the peripheral vasculature prior to further percutaneous intervention. The Kittycat 2 Catheter is contraindicated for use in the iliac, coronary, cerebral or carotid vasculature.
Kittycat 2 is intended to be used to support steerable guidewires in accessing discrete regions of the peripheral vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices. It may also be used to deliver saline or contrast."
AVINGER, INC.
W550`
In Commercial Distribution
- 00851354004042 ()
W550
- Mechanical atherectomy system catheter, peripheral