The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4085
In Commercial Distribution

  • 08806395496570 ()
3300-4085

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4083
In Commercial Distribution

  • 08806395496556 ()
3300-4083

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4081
In Commercial Distribution

  • 08806395496532 ()
3300-4081

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4079
In Commercial Distribution

  • 08806395496518 ()
3300-4079

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4077
In Commercial Distribution

  • 08806395496495 ()
3300-4077

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4075
In Commercial Distribution

  • 08806395496471 ()
3300-4075

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4074
In Commercial Distribution

  • 08806395496464 ()
3300-4074

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4073
In Commercial Distribution

  • 08806395496457 ()
3300-4073

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4072
In Commercial Distribution

  • 08806395496440 ()
3300-4072

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4070
In Commercial Distribution

  • 08806395496426 ()
3300-4070

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4068
In Commercial Distribution

  • 08806395496402 ()
3300-4068

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-4065
In Commercial Distribution

  • 08806395496372 ()
3300-4065

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3075
In Commercial Distribution

  • 08806395496341 ()
3300-3075

  • Spinal fixation plate, non-bioabsorbable
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
GS Medical Co., Ltd.
3300-3073
In Commercial Distribution

  • 08806395496327 ()
3300-3073

  • Spinal fixation plate, non-bioabsorbable
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin.
Instrumentation Difra SA
NysStar II
In Commercial Distribution

  • B516221340 ()
22134

  • Electronystagmograph
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR I is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests). NYSSTAR I is able to record all eye movements, as well horizontal, as vertical and even rotary movements on option. The calibration carried out by NYSSTAR I is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin.
Instrumentation Difra SA
NysStar I
In Commercial Distribution

  • B516221280 ()
22128

  • Electronystagmograph
18mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD9
In Commercial Distribution

  • 1199029 ()
  • M364119902FD90 ()

  • Outer Diameter: 18 Millimeter
  • Length: 21 Millimeter


  • Metallic spinal interbody fusion cage
16mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD8
In Commercial Distribution

  • 1199028 ()
  • M364119902FD80 ()

  • Outer Diameter: 16 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
16mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD7
In Commercial Distribution

  • M364119902FD70 ()


  • Metallic spinal interbody fusion cage
14mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD6
In Commercial Distribution

  • 1199026 ()
  • M364119902FD60 ()

  • Outer Diameter: 14 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
14mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD5
In Commercial Distribution

  • 1199025 ()
  • M364119902FD50 ()

  • Outer Diameter: 14 Millimeter
  • Length: 21 Millimeter


  • Metallic spinal interbody fusion cage
12mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD4
In Commercial Distribution

  • 1199024 ()
  • M364119902FD40 ()

  • Outer Diameter: 12 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
12mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD3
In Commercial Distribution

  • 1199023 ()
  • M364119902FD30 ()

  • Outer Diameter: 12 Millimeter
  • Length: 21 Millimeter


  • Metallic spinal interbody fusion cage
10mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation
MEDICAL DESIGNS LLC
11-9902-FD2
In Commercial Distribution

  • 1199022 ()
  • M364119902FD20 ()

  • Outer Diameter: 10 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
18mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD10
In Commercial Distribution

  • 11990210 ()
  • M364119902FD100 ()

  • Outer Diameter: 18 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
10mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD1
In Commercial Distribution

  • M364119902FD10 ()
  • 1199021 ()

  • Length: 21 Millimeter
  • Outer Diameter: 10 Millimeter


  • Metallic spinal interbody fusion cage
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. HEADSTAR is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus), the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests and the Video Head Impulse Test. HEADSTAR is a nystagmography system and is able to record movements of one eye: horizontal, vertical and rotary on option. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. HEADSTAR is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run VHIT tests and other oculomotor tests.
Instrumentation Difra SA
HeadStar V2.0
In Commercial Distribution

  • B516320980 ()
32098

  • Electronystagmograph
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. NYSSTAR IU is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run specific oculomotor tests.
Instrumentation Difra SA
NysStar II with VOR
In Commercial Distribution

  • B516311790 ()
31179

  • Electronystagmograph
  • Dynamic visual acuity testing system
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. NYSSTAR IU is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run specific oculomotor tests.
Instrumentation Difra SA
NysStar II with VOR
In Commercial Distribution

  • B516227090 ()
22709

  • Electronystagmograph
  • Dynamic visual acuity testing system
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. NYSSTAR IU is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run specific oculomotor tests.
Instrumentation Difra SA
NysStar II with VOR
In Commercial Distribution

  • B516222210 ()
22221

  • Electronystagmograph
  • Dynamic visual acuity testing system
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. HEADSTAR is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus), the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests and the Video Head Impulse Test. HEADSTAR is a nystagmography system and is able to record movements of one eye: horizontal, vertical and rotary on option. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. HEADSTAR is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run VHIT tests and other oculomotor tests.
Instrumentation Difra SA
HeadStar
In Commercial Distribution

  • B516221350 ()
22135

  • Electronystagmograph
primaLOK FF 45mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1145-00
In Commercial Distribution

  • 00813210021990 ()

  • Length: 45 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 40mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1140-00
In Commercial Distribution

  • 00813210021983 ()

  • Length: 40 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 35mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1135-00
In Commercial Distribution

  • 00813210021976 ()

  • Length: 35 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 30mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1130-00
In Commercial Distribution

  • 00813210021969 ()

  • Length: 30 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
primaLOK FF 25mm Implant Assembly, Sterile The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Wenzel Spine, Inc.
800-1125-00
In Commercial Distribution

  • 00813210021952 ()

  • Length: 25 Millimeter


  • Orthopaedic bone screw, non-bioabsorbable, sterile
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-15-24-00
In Commercial Distribution

  • 00813210020023 ()

  • Length: 24 Millimeter
  • Outer Diameter: 15 Millimeter


  • Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-13-24-00
In Commercial Distribution

  • 00813210020016 ()

  • Length: 24 Millimeter
  • Outer Diameter: 13 Millimeter


  • Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-11-24-00
In Commercial Distribution

  • 00813210020009 ()

  • Length: 24 Millimeter
  • Outer Diameter: 11 Millimeter


  • Metallic spinal interbody fusion cage
This Lumbar Back Brace acts as an immobilizing device for the lumbar-sacral region and its’ primary function is to reduce pain caused by lumbago, sciatica and ischialgia. Made with semi-rigid fabric, it enjoys a structure made with self modeling and flexible stays on which a number of rigid straps slide. When the locking system is pulled and secured at the front, the inside straps stiffen the entire structure, thus effectively im- mobilizing the lumbar-sacral region. Two rigid abdominal panels are included. these panels produce intra-abdominal pressure to reduce load on discs thus reducing pain and improving post-operative outcome when used with the corset in the appropriate position. Practical and easy to wear, this brace perfectly adapts to whatever size and body type, thus ensuring maximum support and comfort at the desired tension. through a new locking technology, operated by means of two crossing bands, the closing system is totally user friendly and allows a wide range of tension settings. INDICATIONS •Lumbago, sciatica and ischialgia. •Lumbar-Sacral pain of other origin and nature. •Disc complaints. •Spondylo-arthrosis. •Osteoporosis related lumbar vertebrae complaints. •Para-vertebral lumbar muscle spasm. •Light trauma of the lumbar-sacral column. Recommended for general back pain and support.
INDACO SRL
505 2XL/3XL
In Commercial Distribution

  • 05391512286408 ()
  • 05391512282820 ()
505

  • Lumbar spine orthosis